Valor 500FS Скачать руководство пользователя страница 60

What this warranty does not cover

Repairs to fires which haven’t been installed and commissioned properly and as set

out in the installation instructions.
Faults caused by inadequate supply of gas or electricity (where applicable).
Reimbursement of any third party repair or replacement costs that we haven’t been

told about or agreed with you in advance.
Compensation or consequential losses (e.g. loss of earnings, business losses, stress

and inconvenience) arising from a production breakdown, including repair delays

caused by factors outside our reasonable control.

© 

GDC Group Ltd. SEPT 2016

Page 60

OWNER GUIDE

Содержание 500FS

Страница 1: ...details to enable this appliance to be installed operated and maintained satisfactorily However if further information is required our Valor Technical Helpline will be pleased to help Telephone 0844...

Страница 2: ...ication should be made giving details of the proposed use to the following address The Marketing Communications Manager GDC Group Ltd Millbrook House Grange Dive Hedge End Southampton SO30 2DF Warning...

Страница 3: ...manufactured under a BS EN ISO 9001 quality system accepted by the British Standards Institute The Highest Standards Valor is a member of the Benchark scheme and HHIC Heating and Hot water Industry Co...

Страница 4: ...INSTALLER GUIDE FOR OWNER GUIDE SEE PAGES 45 TO 64 GDC Group Ltd SEPT 2016 Page 4 INSTALLER GUIDE...

Страница 5: ...5 9 Fireplace clearances 17 5 10 Installation options 18 19 5 11 Flues 20 6 PACK CONTENTS 20 7 FIREPLACE CHECK 20 7 1 Soundness for appliance attachment 20 7 2 Fireplace flue pull 23 8 GAS SUPPLY CON...

Страница 6: ...ire RC 30 13 3 2 Adjusting flame height RC 31 13 3 3 Adjusting to pilot only RC 31 13 3 4 Turing off RC 31 13 3 5 Lighting the fire FS 31 13 3 6 Adjusting flame height FS 32 13 3 7 Turning off FS 32 1...

Страница 7: ...aeration settings of the burners 40 18 8 To remove the wall liners 41 18 9 To remove the pilot unit 41 18 10 To remove the Mertik GV60 gas valve RC 42 18 11 To remove the Teddington gas valve and swi...

Страница 8: ...D E A B C C A B A B C B C A GRANDE TRIM EDGE TRIM FRAMELESS Dimension 500FS 500RC Frameless 500FS 500RC Grande Trim 500FS 500RC Edge Trim A 545 mm 582 mm 627 mm B 486 mm 552 mm 597 mm C 25 mm 10 mm 10...

Страница 9: ...walls and ceramic pebbles containing Refractory Ceramic Fibres RCF which are man made vitreous silicate fibres Excessive exposure to these materials may cause irritation to eyes skin and respiratory t...

Страница 10: ...the manufacturer s instructions by competent persons and that it meets the requirements of the appropriate Building Regulations The Benchmark Checklist on the inside back pages of this guide can be u...

Страница 11: ...odel 500 Gas Natural G20 RC Input Max Gross 5 55kW 18 937 Btu hr RC Input Min Gross 3 0kW 10 236 Btu hr FS Input Max Gross 5 55kW 18 937 Btu hr FS Input Med Gross 3 7kW 12 625 Btu hr FS Input Min Gros...

Страница 12: ...een used for this efficiency calculation The conversion of net efficiency to gross was achieved by multiplying the net efficiency by the following conversion factor from Table E3 of SAP 2005 rounding...

Страница 13: ...Installation Inset LFE gas fires BS 6891 Gas pipework installation In England and Wales the current edition of the Building Regulations issued by the Department of the Environment and the Welsh Offic...

Страница 14: ...mance of the appliance Note the spillage test requirements detailed further on in this manual If the fan is likely to affect the appliance the appliance must not be installed unless the fan is permane...

Страница 15: ...und and the bottom front cover to be aligned horizontally Any excessive unevenness uneven tiles Cotswold stone etc should be rectified The appliance must not stand on combustible materials or carpets...

Страница 16: ...in section 5 8 If a hearth is not fitted the fire must be installed so that the distance from the base of the fireplace opening in the wall to the finished floor level is at least 110mm Where there i...

Страница 17: ...imney An approved terminal must be fitted 2 The flue must conform to BS 5440 Part 1 in design and installation The flue measured from the bottom of the fireplace opening to the bottom of the terminal...

Страница 18: ...foam seal 1 off If Frameless trim selected 2 off Inlet T Connector 1 off 8 Button RC Handset 1 off Burner and Convector box unit 1 off Nut and Olive 1 off Wood screw 7 off Cable clamp 2 off Smoke matc...

Страница 19: ...re test point 1 Nut and olive for 8mm inlet pipe 1 Smoke match tube 1 Ember wool 500 Models approx 0 5 gram 1 Slider handle FS only 2 M4 x 8 machine screws FS only to secure the Slider handle 1 Alkali...

Страница 20: ...t and check that there is a definite flow through the flue Verify outside that the smoke exits from one terminal only and that the termination is suitable Observe where possible upstairs rooms and lof...

Страница 21: ...ng by hand the two M5 knurled screws in an anti clockwise direction located just under the base of the door frame Keep these two screws save as they will be needed later Carefully lift out at the base...

Страница 22: ...s a slot to allow the pipe to pass through its center The slot is larger than the 8mm pipe so the remaining open area MUST be sealed with tape after the pipe is located 8 This appliance is supplied wi...

Страница 23: ...powered There are two 1 5 Volt Alkaline AAA size batteries supplied Remove the rear battery compartment cover from the remote control handset Fit the batteries in to the handset Replace the cover 10...

Страница 24: ...reset button Within the subsequent 20 seconds press the DOWN button on the handset until you hear an additional long signal confirming the code is set Please inform the customer that this is a one ti...

Страница 25: ...applicable and place into the generator The negative terminal should go in first The battery is marked with Screw back on the cap 9 7 Checking the ignition operation Push the slider handle to the LEF...

Страница 26: ...ront surround at the marked positions using a suitably sized masonry drill for the wall plugs supplied 5 Insert a wall plug into each hole 6 Place the convection box back in position in the fireplace...

Страница 27: ...st the fireplace front surround Always screw the base into position before applying tension to the cables This will ensure a tight seal between the top of the convection box and wall 5 The convection...

Страница 28: ...crews in the retainers and apply tension to the cables by turning the hexagonal adjusters clockwise as far as possible 12 Feed the free length of the cables through the small holes in the back of the...

Страница 29: ...lass side wall liners Inside the accessory box you will find two metal spacer brackets and 4 screws Locate the glass liner spacer to the LHS and RHS of the convection box using the 4 screws supplied N...

Страница 30: ...on from the rear The T connector includes a valve for isolating the gas supply The supply pipe must be rigid material Flexible pipe must not be used Connect the supply line to the appliance 2 If close...

Страница 31: ...Repeat these steps with the two burners ignited 13 3 3 Adjusting to pilot only setting When the burner is operating press and hold the DOWN button until the burner flame extinguishes To turn the main...

Страница 32: ...tting on the Slider FS models 13 3 7 Turning off To turn the fire off push the slider as far as possible to the RHS 13 4 Check inlet pressure The appliance is pre set to give the correct heat input at...

Страница 33: ...ll the gap between the top tray and the rear glass liner This can be found in the accessory kit 14 3 Positioning the ember wool across the burners The fire is supplied with a bag of ember wool 500 mod...

Страница 34: ...ure it 15 FULL OPERATING CHECKS 15 1 Check the burner operation Repeat the checks conducted in section 13 3 Please note When first turned on from cold the flames will appear predominantly blue When op...

Страница 35: ...above test is satisfactory open all internal connecting doors hatches etc in the room Keep all doors and windows that open to the outside of the building closed Recheck for spillage as above If an ex...

Страница 36: ...de metal return on the outer convector box Push the trim tight up to the fire ensuring that the magnets are fully incontact and holding the trim in place 2 Frameless The frameless trim is pre fitted w...

Страница 37: ...operate to its maximum potential if the flue is primed during the first 20 30 minutes of use To do this simply set the control to its highest setting This will also burn off any carbon deposits that m...

Страница 38: ...the fire When replacing these articles we recommend that the replaced items are not broken up but are sealed within a heavy duty polythene bag clearly labelled as RCF waste RCF waste is classed as a s...

Страница 39: ...y unscrewing by hand the two M5 knurled screws in an anti clockwise direction located just under the base of the door frame Keep these two screws save as they will be needed later Carefully pully out...

Страница 40: ...and tray 1 Complete section 19 1 19 6 2 Isolate the gas supply at the inlet isolating T connector 3 Support the inlet T connector to avoid straining the pipework and disconnect the appliance from the...

Страница 41: ...s gently push out the liner till flat inside the convector box then angle to remove being careful not to rub the edges off the inner convector box 6 Replace in the reverse order 18 9 To remove the pil...

Страница 42: ...on the base of the tabs and not the leads It is important that when replacing the leads that the lead with the larger tag From the receiver is furthest away from the valve body 4 Detach the pilot pip...

Страница 43: ...nerator will lift up and away 6 Detach the pilot pipe from the gas valve 7 Detach the inlet pipe 8 Detach the front burner pipe 9 Detach the rear burner pipe 10 The valve is conected to the slider ass...

Страница 44: ...clamping plate from the upper right hand side of the burner Remove all three screws for ease See figure 38 3 Unscrew and remove the injector cover plate from underneath the burner See figure 39 4 Sup...

Страница 45: ...Page 45 GDC Group Ltd SEPT 2016 OWNER GUIDE OWNER GUIDE FOR WARRANTY SERVICE AND BENCHMARK INFORMATION SEE PAGES 58 TO 63...

Страница 46: ...54 Trim Metal and painted parts 54 Removing and cleaning the window assembly 54 Ceramic fuel effect log pieces and convector box compartment walls 54 Burner 55 MAINTENANCE 56 Battery replacement 56 RC...

Страница 47: ...NSIONS C A B A B C B C A FRAMELESS GRANDE TRIM EDGE TRIM Dimension 500FS 500RC A 574 mm B 546 mm C 267 mm D 496 mm E 549 mm Dimension 500FS 500RC Frameless 500FS 500RC Grande Trim 500FS 500RC Edge Tri...

Страница 48: ...earance of 300mm from the side of the appliance not the trim Please bear this in mind if ever you are considering altering the room Do provide a suitable guard that complies with BS 8423 for the prote...

Страница 49: ...of depth add 25mm above the 400mm from the top of the appliance not the trim Don t hang clothing towels or any other fabrics over the fire Don t add any ceramic fuel effect pieces to the burner This c...

Страница 50: ...off the gas supply to the fire if the pilot flame goes out due to lack of oxygen or for any other reason If this device starts to repeatedly shut off the gas get expert advice This device incorporates...

Страница 51: ...tandby mode Pliot flame Flame height adjustment Designated Low fire and High fire Countdown Timer Modes of operation Thermostatic mode Programe mode Eco mode Auxiliary feature Rear burner operation Li...

Страница 52: ...ilot can be seen through the cutout at the middle front of the burner openeing To turn the main burner on again simply press and hold the UP arrow button To turn off To turn the fire off press the OFF...

Страница 53: ...perating step the slider handle to the RHS increments will be felt as the slider moves giving you the following outputs Position 1 After ignition burner on LOW Position 2 Moving slider handle one incr...

Страница 54: ...d Any stains on the glass can be removed with a non abrasive cleaner such as a ceramic hob cleaner Never use abrasive cleaners Clean the window carefully in accordance with the instructions supplied w...

Страница 55: ...est that you remove the ceramic fuel effect pieces in the reverse order to that shown in the ceramic fuel effect installer and owner guide Once cleaned replace the log fuel effect as in ceramic fuel e...

Страница 56: ...pull forward to remove The battery pack is now accesable lift it up and out carefully Open and slide the battery compartment cover clear Remove the existing batteries Fit four Alkaline 1 5 Volt AA siz...

Страница 57: ...t a landlord must have any gas appliance flue and pipework which is situated in a tenant s premises checked for safety at least every twelve months by a competent person GAS SAFE REGISTER operative We...

Страница 58: ...k Checklist on the inside back pages of the installation instructions supplied with the product and that you have signed it to say that you have received a full and clear explanation of its operation...

Страница 59: ...call our UK Helpline on 0844 879 35 88 or from the Republic of Ireland on 01 842 8222 for any general advice that you may need When calling the Helpline it would be helpful if you could have the follo...

Страница 60: ...ectricity where applicable Reimbursement of any third party repair or replacement costs that we haven t been told about or agreed with you in advance Compensation or consequential losses e g loss of e...

Страница 61: ...O V WKH KHDUWK D PLQLPXP RI PP WKLFN ZLWK D PLQLPXP RRU WR WRS VXUIDFH RI PP 6 RU DV SHU PDQXIDFWXUHU V LQVWUXFWLRQV V WKH KHDUWK IRU RSHQ IURQWHG UHV D PLQLPXP RI PP ZLGH DQG KDV PP SURMHFWLQJ IURP W...

Страница 62: ...PH RPSDQ QDPH 7HOHSKRQH 1R DV VDIH UHJLVWHU 1R RPPHQWV 6LJQDWXUH SERVICE 03 DWH QJLQHHU QDPH RPSDQ QDPH 7HOHSKRQH 1R DV VDIH UHJLVWHU 1R RPPHQWV 6LJQDWXUH SERVICE 04 DWH QJLQHHU QDPH RPSDQ QDPH 7HOHSK...

Страница 63: ...Page 63 GDC Group Ltd SEPT 2016 A LABEL CONTAINING THE SERIAL NUMBER AND BARCODE MAY HAVE BEEN PLACED INSIDE THIS BOX SERIAL NUMBER LABEL TO BE AFFIXED HERE OWNER GUIDE...

Страница 64: ...Page 64 GDC Group Ltd SEPT 2016 OWNER GUIDE...

Отзывы: