7
WARNING
CHOKING HAZARD!
Ensure that the
fi
replace
area is clear of
fi
re glass or vermiculite particles as
these could be ingested by small children. Vacuum
thoroughly around the
fi
replace area after cleaning.
Long Beach Driftwood Kit Correct Flame Picture
Murano Glass Fire Correct Flame Picture
Pilot Flame can
be seen left of
the fi re bed
Pilot Flame can be seen
between the front and
rear left logs
WARNING
FOR SAFETY PURPOSE, ensure the barrier
FOR SAFETY PURPOSE, ensure the barrier
screen is re-installed on the fi replace front
screen is re-installed on the fi replace front
after maintenance.
after maintenance.
!
Pilot Flame
Thermocouple Probe
must be in Flame
To refi t the window:
1. Place it in its bottom railing and push its top against
the
fi
rebox.
2. While you hold it, pull the side levers back into the
window brackets on each side.
3. Apply light hand pressure against the window frame
sides to bed-in the window seal.
4.
If the Hot Glass Warning plate has been removed
from the front lower corner of the window,
reinstall it by sliding it between the glass and
the frame as indicated.
5.
Reinstall the barrier screen on the trim.
a)
1755 1” trim:
Insert the screen’s top tabs in the
slots in the convection baf
fl
e then rest the screen
bottom tabs on the edge of the opening in the
plinth to lock it in position.
b)
1750 5.1/4” trim:
Hook the bottom of the screen
to the bottom edge of the trim’s front plate, then,
with the top levers up, push the screen against
the
fi
replace. Rotate the levers down to hook
them up to the trim and slide them inwards to
secure them.
6. Verify that the screen is properly hooked to the trim
and secure.
Owner’s Information
IMPORTANT:
To ensure a safe operation, verify
that the levers are hooked properly to the window
tabs; then, pull out the top of the window and
release it to insure the springs return it.
!
Hot Glass Warning Plate
Checks
A periodic check of the pilot and burner
fl
ames should
be made. Check after the
fi
re has been on for at least
30 minutes. The pilot
fl
ame must cover the tip of the
thermocouple probe. The main burner
fl
ame pattern will
vary from appliance to appliance depending on the type
of installation and climatic conditions.
The appliance area must always be kept clear and
free from combustible materials, gasoline and other
fl
ammable vapors and liquids.
Inspect the vent terminal outdoors regularly to make
sure that snow, trees, bushes, leaves, or other objects
do not obstruct it.
Examine the vent system and terminal regularly. We
recommend annually.
Remote Control Handset Wall
Holder
Your
fi
replace equipment includes a wall
holder to store the handset. If it hasn’t be
installed, refer to the instructions further
on in this manual for the installation.
OWNER’S