Valor 1500KP Скачать руководство пользователя страница 4

4

This manual contains very important information about the safe operation and maintenance of your 

fi

 replace. 

Read and understand all instructions carefully before operating your 

fi

 replace. Failure to follow these 

instructions may result in possible 

fi

 re hazard and will void the warranty.

Replacement manuals are available by contacting Valor Customer Service at 1-800-468-2567, or by visiting 

valor

fi

 replaces.com

.

 

WARNING: Extremely Hot!

Heat and 

fl

 ammability

• Some parts of your 

fi

 replace are extremely hot, 

particularly the glass window.  Use the  provided bar-

rier screen and a  gate to reduce the  risk of severe 

burns.

• The glass windows can exceed temperatures of 

500°F at full capacity.

• Always keep the appliance clear and free from com-

bustible materials, gasoline, and other 

fl

 ammable 

vapors and liquids. 

• Be aware of hot wall surfaces. The wall directly 

above the 

fi

 replace can get very hot when the 

fi

 re-

place heats. Although safe, it may reach tempera-

tures in excess of 200º F depending on choice of 

trims or optional accessories. Do not touch!  

• Be aware of hot surfaces in front of the 

fi

 replace 

windows. A shelf directly in front of the 

fi

 replace 

can get very hot when the 

fi

 replace heats. Although 

safe, they may reach temperatures in excess of 200º 

F depending on elevation of the shelf. Do not place 

anything on it.

• Some materials or items, although safe, may dis-

color, shrink, warp, crack, or peel due to the heat 

produced by the 

fi

 replace. Avoid placing candles, 

paintings, photos and other combustible objects 

sensitive to heat or furniture within 36 inches 

(0.9 m) around the 

fi

 replace.

• Due to its high temperature, the appliance should 

be located away from high-tra

  c areas, furniture, 

and draperies.

• Clothing or 

fl

 ammable material should not be 

placed on or near the appliance.

Glass window

• The glass window fronts must be in place and 

sealed before the unit can be placed into safe op-

eration.

• The glass fronts must only be replaced as complete 

units, as supplied by the 

fi

 replace manufacturer. No 

substitute material may be used.

• Do not use abrasive cleaners on the glass front 

assembly. Do not attempt to clean the glass front 

when it is hot.

• Do not strike or slam the glass fronts.

Safety and your fireplace

WARNING

Do not operate this appliance with 

the glass fronts removed, cracked, or 

broken. Replacement of the glass fronts 

should be performed by a licensed or 

quali

fi

 ed service person.

Do not put

 

furniture or other objects 

in this space in front of 

the fireplace:

36” (0.9 m)

Fireplace

Hearth

Содержание 1500KP

Страница 1: ...supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified install...

Страница 2: ...rohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convertible for use with other gases unless a certified kit is used INS...

Страница 3: ...____ Options ________________________________________ ________________________________________________ ________________________________________________ Please ask your installer for these details if t...

Страница 4: ...ce can get very hot when the fireplace heats Although safe they may reach temperatures in excess of 200 F depending on elevation of the shelf Do not place anything on it Some materials or items althou...

Страница 5: ...d service technician to inspect the appliance and to replace any part of the control system and any gas control that has been under water Intended use This appliance is designed and approved as a supp...

Страница 6: ...rvised when they are in the same room as the appliance Toddlers young children and others may be sus ceptible to accidental contact burns A physical barrier is recommended if there are at risk individ...

Страница 7: ...m the pilot flame If the probe is cool the device will prevent any gas flow unless manually lighting the pilot See the full Fireplace and Lighting Information card attached to the fireplace or as repr...

Страница 8: ...et OPTIONAL Parts of your fireplace Here are the major components of your installed fireplace with the protective barrier installed Your individual fireplace may appear differently depending on your i...

Страница 9: ...r fireplace OFF including pilot Press and hold button on remote or ON OFF button on wall switch If the flames or pilot are on they will go out and you will hear the valve motor wind down You will hear...

Страница 10: ...ace will not turn on unexpectedly On gas valve turn dial from ON position to MAN position as shown Turning dial to MAN will ensures that main burner cannot come on The pilot will remain on if lit Alte...

Страница 11: ...n the remote wall switch no tools required and withdraw the battery holder straight out from the wall it is attached to the plate Replacing batteries WARNING Do not attempt to access the batteries whi...

Страница 12: ...glass cleaner Abrasive cleaners must not be used Be careful not to scratch the glass when cleaning See Cleaning your fireplace on page 13 Inspect the operation of the flame safety sys tem Pilot or Fla...

Страница 13: ...ors by lifting and unhooking them Lift the plinth to remove it 3 1700K L2 models only Remove the plinth support bracket Remove plinth Remove side doors 4 Locate the levers on each side of the window t...

Страница 14: ...y Rutland Turtle Wax Do not clean the glass while it is hot Always securely replace the windows and the bar rier screen before lighting see next page If broken glass panes may only be replaced as a co...

Страница 15: ...ARNING The window unit must be correctly installed fastened and sealed after servicing or serious bodily injury and or damage to the appliance may result To ensure a safe operation Double check that t...

Страница 16: ...models only Reinstall the plinth sup port bracket hooking it up to the sti ener bracket located below the window as shown Plinth support bracket Sti ener bracket 8 Reinstall the plinth and side doors...

Страница 17: ...ct the vent terminal outdoors regularly to ensure that it is not obstructed by snow trees bushes leaves or other objects We recommend at least an annual inspection Checking pilot and burner flames Pil...

Страница 18: ...pilot and burner flames Typical flame appearance L2 Driftwood log kit Splitwood kit Decorative Murano Glass kit Pilot Light Pilot Light Pilot Light Rock Shale kit Birch Log kit Pilot Light Pilot Light...

Страница 19: ...s in your remote control handset but the batteries in the battery holder beside the wall switch See page 11 for instructions on how to replace the batteries Why do I hear popping or snapping noises As...

Страница 20: ...our fireplace serviced before initial use and at least once every year by a qualified service technician Contact our dealer quoting the model and serial numbers if possible These numbers can be found...

Страница 21: ...form to all applicable codes including national and local gas appliance installation codes and building and re codes d The owner must comply with all operating instructions e The Company is not respon...

Страница 22: ...install repaired or replacement parts f The initial owner of the unit will be responsible for any shipping charges for replacement parts as well as travel time incurred by the dealer to perform the w...

Страница 23: ...if included Program Mode Temperature Time Auxiliary Feature not used Countdown Timer Battery Status Eco F or C To Turn On Fire One Button lighting default Two Button lighting simultaneously Press and...

Страница 24: ...untdown Timer AM AM To deactivate functions 1 Install batteries All icons are displayed and ashing 2 While the icons are ashing press the relevant func tion button and hold for 10 seconds 3 The functi...

Страница 25: ...r only works in Manual Thermostatic and Eco modes Maximum countdown time is 9 hours and 50 minutes Light Dimmer Operation On Press is displayed Light is on at preset level Off Press disappears Light t...

Страница 26: ...anual Mode The on o status of the replace as well as ame height are manually controlled by the user PM ON OFF PM PM Thermostatic Mode On Press is displayed Preset temperature displays brie y followed...

Страница 27: ...ing PROGRAM 1 1 1 OFF are displayed ALL is displayed brie y Hour ashes 2 To select hour press or 3 To con rm press 1 OFF are displayed ALL displayed brie y Minutes ash 4 To select minutes press or 5 T...

Страница 28: ...0 minutes CAUTION Do not use a screwdriver or other metallic object to remove the batteries from the battery holder or the handset This could cause a short circuit Low Battery Receiver With low batter...

Страница 29: ...ilot supply line No spark Reversed polarity in thermocouple wiring Incorrect pilot ori ce if valve has been converted from LPG to NG or vice versa F07 Low battery symbol Permanent Battery icon ashes o...

Страница 30: ...ss and hold large flame button to gradually increase flame height Press and hold small flame button to gradually decrease flame height The Wall Switch can be used to control your fireplace You can tur...