Note
Use of V2 log sets may increase the possibility of
soot formation when the air shutter is closed. The
L1 units are fitted with an air shutter stopper to
prevent closing the aeration completely in order
to prevent sooting in most situations. However, it
is still possible that some sooting may occur under
certain conditions.
Evaluate the flame picture carefully after the unit
has warmed up for fifteen minutes, and avoid
closing the air shutter completely when there is
limited rise in the venting system or the flame
appears overly luminous and lazy with smoke
trailing off the flame tips.
Refer to “Checking Operation and Aeration” on
page 57 for details about aeration adjustment.
Driftwood Kit 1505DWKV2
Material required
• Black steel platform (supplied with appliance)
• Driftwood Kit containing:
• 6
logs
• 6
pebbles
• 1 bag of vermiculite, 5-1/2 cups
• Gloves, if desired, not included
Installation
Carefully unpack the kit. Note each log has its own
number stamped on the bottom. Some logs have pegs
to help you place them on other logs or the platform.
Install the logs as follows.
1. Install the steel platform around the burner as
indicated. The openings in the platform should be
underneath.
2. Carefully spread some of the vermiculite on the
surface of burner patting it gently with your hand to
form a single layer to the approximate level of the
top of the
fl
ange at the edge of the burner. Do not
pour too much to avoid blocking the burner ports.
NOTE:
Ensure the area within the pilot shield is
clear of vermiculite.
Installed platform