Valor 1100MN Скачать руководство пользователя страница 23

23

Appendix A-Remote Control Operation

Designated Low Fire and High Fire

To go to low 

ȴ

 re, double-click  . “LO” 

is displayed.

Note:

 Flame goes to high 

ȴ

 re 

ȴ

 rst 

before going to low 

ȴ

 re.

To go to high 

ȴ

 re, double-click  . “HI” 

is displayed.

 Choosing 1-Button or 2-Button Ignition

On the remote control handset, you can choose a 
1-button or 2-button ignition. You can also choose to 
activate or deactivate some of the functions. By default, 
the handset is set to a 1-button ignition.

To change from 1-button to 2-button ignition, remove 
the batteries, wait 10 seconds, reinsert batteries, and 
immediately when the display 

ȵ

 ashes, press and hold 

the   button for 10 seconds. 

ON

 is displayed and 

1

 is 

ȵ

 ashing. When change is complete, 

1

 changes to 

2

.

To change from 2-button to 1-button ignition, proceed 
the same as above. 

ON

 is displayed and 

2

 is 

ȵ

 ashing. 

When change is complete, 

2

 changes to 

1

.

Deactivating or Activating Functions

These functions are active by default, but can be 
deactivated at any time:

• Child Proof
• Program Mode
• Thermostatic Mode
• Eco Mode
• Circulating Fan Operation
• Countdown Timer

AM

AM

To deactivate functions:

1.  Install batteries. All icons are displayed and 

ȵ

 ashing.

2.  While the icons are 

ȵ

 ashing, press the relevant func-

tion button and hold for 10 seconds.

3.  The function icon will 

ȵ

 ash until deactivation is com-

plete. Deactivation is complete when the function 
icon and two horizontal bars (

) are displayed.

Note:

 If a deactivated button is pressed, there is no 

function, and the two horizontal bars are displayed.

To activate functions:

1.  Install batteries. All icons are displayed and 

ȵ

 ashing.

2.  While the icons are 

ȵ

 ashing, press the relevant func-

tion button and hold for 10 seconds.

3.  The function icon will continue to 

ȵ

 ash until activa-

tion is complete, and then turn solid. Activation is 
complete when the function icon is displayed.

Setting Celsius or Fahrenheit

To change between °C and °F, press 
and hold   +   simultaneously.

Note :

 °C = 24-hour clock

             °F = 12-hour clock

Setting the Time

1. Press   +   simultaneously. 

Day

 

ȵ

 ashes.

2. Press   +   to select a number 

to correspond with the day of the 
week.

• 1 = Monday
• 2 = Tuesday
• 3 = Wednesday
• 4 = Thursday
• 5 = Friday
• 6 = Saturday
• 7= Sunday

3. Press   +   simultaneously. 

Hour

 

ȵ

 ashes.

4.  To select hour press   or  .
5. Press   +   simultaneously. 

Minutes

 

ȵ

 ash.

6.  To select minutes press   or  .
7. To 

con

ȴ

 rm, press   +   simultaneously or wait.

PM

PM

AM

Содержание 1100MN

Страница 1: ...gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified in...

Страница 2: ...market permanently located manufactured mobile home where not prohibited by local codes This appliance is only for use with the type of gas indicated on the rating plate This appliance is not convert...

Страница 3: ...___________________ ________________________________________________ Please ask your installer for these details if they are not already provided or see page 7 Welcome to Valor Contents Safety and you...

Страница 4: ...ts Although safe they may reach temperatures in excess of 200 F depending on elevation of the shelf Do not place anything on it Some materials or items although safe may dis color shrink warp crack or...

Страница 5: ...while attended The use of an alternate primary heat source is advisable This unit is not for use with solid fuel Do not use this heater as a temporary source of heat during construction WARNING Do not...

Страница 6: ...n they are in the same room as the appliance Toddlers young children and others may be sus ceptible to accidental contact burns A physical barrier is recommended if there are at risk individuals in th...

Страница 7: ...flames will be at their normal height Valor automatic gas shut o For your safety Valor fireplaces are fitted with a flame supervision device which will shut o the gas supply if for any reason the pil...

Страница 8: ...ndividual fireplace may appear differently depending on your installed options Barrier Screen Window Frame Window Frame Liner Panels Side Door Fireplace info card behind right door Fuel Bed Burner Pla...

Страница 9: ...Press and hold button on remote or ON OFF button on wall switch If the flames or pilot are on they will go out and you will hear the valve motor wind down You will hear a clunk and a beep indicating t...

Страница 10: ...fireplace will not turn on unexpectedly On gas valve turn dial from ON position to MAN position as shown Turning dial to MAN will ensures that main burner cannot come on The pilot will remain on if li...

Страница 11: ...he fireplace is hot Let the fireplace cool first before touching it Caution Do not use a screwdriver or other metallic object to remove the batteries from the battery holder or the handset This could...

Страница 12: ...cleaner Abrasive cleaners must not be used Be careful not to scratch the glass when cleaning See Cleaning your fireplace on page 13 Inspect the operation of the flame safety sys tem Pilot or Flame re...

Страница 13: ...he tabs on the doors then pulling straight towards the center of the fireplace 3 Remove the removable panel pulling it straight towards you 4 Locate the window latch pull handle on the bottom of the f...

Страница 14: ...If broken glass panes may only be replaced as a complete window unit as supplied by the manufac turer If the barrier screen becomes damaged it must only be replaced with the same model and version ba...

Страница 15: ...tly can Leak carbon monoxide Affect the performance of the fireplace Damage components Cause overheating resulting in dangerous conditions Damage caused by incorrect window installation is not covered...

Страница 16: ...plate has been removed from the front lower corner of the window reinstall it by sliding it between the glass and the frame as indicated 6 Re install the removable panel inserting it in the clips on e...

Страница 17: ...the vent terminal outdoors regularly to ensure that it is not obstructed by snow trees bushes leaves or other objects We recommend at least an annual inspection Checking pilot and burner flames Drift...

Страница 18: ...low not the batteries in your remote control handset but the batteries in the battery holder beside the wall switch See page 11 for instructions on how to replace the batteries Why do I hear popping...

Страница 19: ...for a list of dealers near you Who can service my fireplace We recommend having your fireplace serviced before initial use and at least once every year by a qualified service technician Contact our de...

Страница 20: ...form to all applicable codes including national and local gas appliance installation codes and building and re codes d The owner must comply with all operating instructions e The Company is not respon...

Страница 21: ...install repaired or replacement parts f The initial owner of the unit will be responsible for any shipping charges for replacement parts as well as travel time incurred by the dealer to perform the w...

Страница 22: ...if included Program Mode Temperature Time Auxiliary Feature not used Countdown Timer Battery Status Eco Mode F or C To Turn On Fire One Button lighting default Two Button lighting simultaneously Pres...

Страница 23: ...untdown Timer AM AM To deactivate functions 1 Install batteries All icons are displayed and ashing 2 While the icons are ashing press the relevant func tion button and hold for 10 seconds 3 The functi...

Страница 24: ...r only works in Manual Thermostatic and Eco modes Maximum countdown time is 9 hours and 50 minutes Light Dimmer Operation On Press is displayed Light is on at preset level Off Press disappears Light t...

Страница 25: ...WiFi the handset will display APP Manual Mode The on o status of the replace as well as ame height are manually controlled by the user PM ON OFF PM PM Thermostatic Mode On Press is displayed Preset t...

Страница 26: ...N ON Off Time Setting PROGRAM 1 1 1 OFF are displayed ALL is displayed brie y Hour ashes 2 To select hour press or 3 To con rm press 1 OFF are displayed ALL displayed brie y Minutes ash 4 To select mi...

Страница 27: ...imum countdown time is 9 hours and 50 minutes CAUTION Do not use a screwdriver or other metallic object to remove the batteries from the battery holder or the handset This could cause a short circuit...

Страница 28: ...no pilot ame No gas supply Air in pilot supply line No spark Reversed polarity in thermocouple wiring Incorrect pilot ori ce if valve has been converted from LPG to NG or vice versa F07 Low battery s...

Страница 29: ...ss and hold large flame button to gradually increase flame height Press and hold small flame button to gradually decrease flame height The Wall Switch can be used to control your fireplace You can tur...

Страница 30: ...30 Notes...

Отзывы: