![Valor 1000KN Скачать руководство пользователя страница 11](http://html1.mh-extra.com/html/valor/1000kn/1000kn_installation-manual_3282191011.webp)
11
Caution
ONLY qualified licensed or trained personnel
should install this appliance
NEW CONSTRUCTION
1030CIK Clean Installation Kit
YES
Covers kit, butts to
fl
ange
Flush or max 1-1/2” above
bottom of appliance.
Note:
Micore
pad required if
hearth surface is above
appliance base.
1035BPB 3-Sided backing plate +
1045CFV Clearview Front
YES
Backing plate adjusts to allow for thickness
of non-combustible
fi
nish added over top of
cement board.
Max. thickness on top of cement board: 3/4”.
Flush to bottom of appliance
1040BPB 4-Sided backing plate +
1041FS 4-Sided Surrounds
YES
Min. 1/4” BELOW bottom of
appliance
Backing plate trim
combination
1/2” cement
board required
above
appliance
Wall
fi
nish
Hearth position (if any)
RETROFIT INSTALLATION—Reduced Clearance
1035BPB-RC 3-Sided backing plate +
1045CFV Clearview Front
NO
Existing wall
fi
nish.
Note: When top venting, max. existing wall
fi
nish thickness, including header, is approx.
5”, maintaining 1” clearance to vent.
Flush to bottom of appliance
1036BPB-RC 3-Sided tall backing
plate + 1045CFV Clearview Front
NO
Flush to bottom of appliance
1040BPB-RC 4-Sided backing plate +
1041FS 4-Sided Surrounds
NO
Min. 7/8” BELOW bottom of
appliance
Summary
Applications
There are two types of applications for the H3:
NEW CONSTRUCTION APPLICATION—
Pages 11–17
New construction applications where new framing
is being built and new wall
fi
nish applied. These
installations require the use of a non-combustible
cement board immediately above the
fi
replace and a
header of a minimum height of 39” from the base of the
H3 appliance.
RETROFIT APPLICATION with RC PLATES—
Pages 18–19
Retro
fi
t applications where an existing
fi
replace is being
removed, and the existing wall
fi
nish and cavity remain.
These installations allow for a lower combustible header
height of 33”, and combustible wall
fi
nishes within 31” of
the base of the H3 appliance.
Installation Planning
NOTE
RC type Backing Plates are NOT compatible
to use with the HeatShift System.