background image

16 

Output 

Output kW 

Brunswick 

Cycle 

Hours 

Anthracite 

4.6 

Wood Logs (less than 20% moisture) 

4.9 

Coal  (E) 

4.3 

Peat  (E) 

4.7 

Closed Fire Briquettes   

4.6 

Outputs stated are under ideal test conditions. Variations will occur due to installation, atmospheric condi-
tions and fuel quality. 
(E) - estimate calculated 

 

Flue Gas 

Temp at 

Spigot 

Flue Gas  

Mass Flow 

Flue Diam 

Ventilation 

Reqt 

Ventilation Reqt 

with draught 

stabilizer 

Brunswick 

446

O

3.4 g/s (wood) 

4.7 g/s (ancit) 

125mm  

5 inches 

None 

1500mm

2

 

2.33in

2

 

As tested to the requirements of EN13240 for intermittent use.  

Valor Fires  

Wood Lane  

Erdington  

Birmingham  

B24 9QP 

 

Tel. 01204 868550 (technical and spares enquiries)

  

 

www.valor.co.uk 

  

BRUNSWICK 

CAST IRON MULTI-FUEL STOVE  
V 5.2 
Conforms to EN13240:2001  
Constructional Requirements 
For Intermittent Use 
Not to be used in a shared flue 

BRUNSWICK 

INSTALLATION AND OPERATING INSTRUCTIONS 

(to be left with the householder) 

FIRES CAN BE DANGEROUS –The Brunswick Stove operates at very high temperatures. 
Always use a fire guard to BS6539 specification in the presence of children, the elderly of the 
infirm. Inform all persons the dangers of high temperatures during operation of appliance in-
cluding the stove pipe use operating tools provided. The mitten provided is a tool. 

APPROVED 

Содержание BRUNSWICK

Страница 1: ...N13240 for intermittent use Valor Fires Wood Lane Erdington Birmingham B24 9QP Tel 01204 868550 technical and spares enquiries www valor co uk BRUNSWICK CAST IRON MULTI FUEL STOVE V 5 2 Conforms to EN...

Страница 2: ...In Wg Dimensions may vary slightly the manufacturers reserve the right to adjust them without notice Key To Dimensions A Height B Width C Centreline of Flue D Height To Centre of Rear Flue E Depth F...

Страница 3: ...010 Leg 14 15 D11C002 Stove Door Front Panel 16 FFX014 Ash Pan 17 FFX011 Fret 18 FFX024 Secondary Air Duct 19 FFX018 Door Glass 20 FFX027 Glass Panel Seal 21 FFX026 Door Seal 22 FFX023 Secondary Air S...

Страница 4: ...ion Instructions Check the chimney is in good condition dry free from cracks and obstructions The diameter of the chimney flue should not be less than 150mm and not more than 230mm If any of these req...

Страница 5: ...lacken the two screws beneath the grate and pull forward then close the door fully open door and tighten screws Positioning of Appliance The stove can be recessed in a suitable sized fireplace but a p...

Страница 6: ...arket product and will be of the type with positive open and closed indication to prevent misunderstanding THE FLUE DAMPER SHOULD NOT BE FITTED WHEN BURNING SOLID FUELS De Ashing It is important that...

Страница 7: ...he air flow through the grate and eventually cause the fire to die With some solid fuels a residue of burnt fuel or clinker will accumulate on the grate al low the fire to go out periodically to remov...

Страница 8: ...brick lin ings check operation of grate check flue for any possible blockages It is advisable to have the chimney swept at least once or even twice per year If the appliance is in con 9 stant use the...

Отзывы: