11.
Pull each cable taut. Push the cable retainers hard up against the back panel. The
end of the cable adjuster will pass
into the hole. Tighten the screws in
the retainers so that they clamp the
cables in position. Apply tension to
the cables by turning the hexagonal
adjusters by hand (See figure 22).
12.
Inspect the installation of the
hotbox against the fireplace surround.
If the hotbox is aligned squarely and
the sealing is satisfactory, fully tighten
the cable retainers.
13.
If the hotbox is not correctly
aligned, release the tension on the
cables by slackening the screws and
turning the hexagonal adjusters fully
anticlockwise. The hotbox should
then automatically realign itself. Pull
each cable taut again and push the
cable retainers back against the back
panel. Again, tighten the screws in
the retainers and apply tension to the cables by turning the hexagonal adjusters
clockwise as far as possible.
14.
Feed the free length of the cables into the gap between the inner and outer back
panels so that they are available to allow easy removal and refitting of the appliance
during subsequent service calls.
Do not cut off the free lengths of cable.
9.3 Sealing floor front - All installations
Using the floor sealing tape supplied, seal the bottom of the hotbox to the fireplace
and hearth floor (See figure 23).
Make sure that the whole length of the front
edge of the hotbox is fully sealed.
Page 29
©
Baxi Heating U.K. Limited 2009.
INSTALLER GUIDE
Figure 22. Lower cable retention
Figure 23. Floor sealing