9 Configuration
Select
Esc
in
Main result display
to get to
Main
menu
.
Then select
1 Configuration
from
Main menu
.
9.1 Recipe selection
Press
Edit
>
Save
to select a recipe to edit.
Recipe mode:
•
1–4:
Manual, fixed recipe selection.
•
5:
Digital input, remote control via binary
inputs. When remote selection is activated,
it overrides fixed recipe selections by the
operator, and the active recipe is selected
instead by the digital inputs of TCU. Re-
motely selected recipe is indicated in the
measurement display with letter "R" after
the recipe number.
9.2 Output signal 1
LRV
= Lower range value: The consistency
percentage that produces the 4 mA analog out-
put signal. Default, 0.5 % Cs.
URV
= Upper range value: The consistency percentage that produces the 20 mA
analog output signal. Default, 7.0 % Cs.
Configuration | 29 (48)
K20798 V1.1 EN - 1 - 12/2019