4EXP70EN - 9/2023
2 General safety instructions
The symbols in Table 1 are used in this manual to highlight
the parts requiring particular attention.
Hazard severity panels.
DANGER!
DANGER indicates a hazard with a high level of risk
which, if not avoided, will result in death or serious injury.
WARNING!
WARNING indicates a hazard with a medium level of
risk which, if not avoided, could result in death or serious
injury.
CAUTION!
CAUTION indicates a hazard with a low level of risk
which, if not avoided, could result in minor or moderate
injury.
Table 1.
Warning and safety signs.
Symbol
Description
Risk to personal safety:
Neglecting the safety measures can cause serious injury
or death.
Read the operation and maintenance instructions:
Read and understand the operation and maintenance
instructions before using the product.
Mandatory action symbol:
Obey these instructions to prevent machine
malfunctions.
Forbidden action symbol.
Prevent accidents and ensure the inline pulsation dampener’s
appropriate operation by complying with the installation,
safety, and maintenance instructions in this manual.
Installation and maintenance of the dampener must be
carried out by persons with appropriate training.
Access to the IOM-manual must be guaranteed at all times at
the place of operation of the inline pulsation dampener. It is
required to observe the IOM-manual in all work tasks for the
dampener.
Use personal protective equipment when performing any
checks or maintenance operation for the inline pulsation
dampener (goggles, helmet, clothing and gloves). Always
follow the factory safety regulations.
In case of any discrepancies between translations, the English
version shall prevail.
3 Introduction
3.1 Applications and purpose of use
Flowrox Expulse™ is a flexible inline pulsation dampener,
which smoothes noises, restless pipes, pressure peaks and
uneven flows. The design is based on double hose structure;
damping hose, cover hose and compressed air in between. It
may be installed on a pulsating pump from any manufacturer
in the market.
The dampener is self-cleaning and does not collect sediment
or particles. It is resistant to wearing, corrosion and most
chemicals.
Flowrox Expulse™ provides a flexible connection to the pump
and tolerates possible misalignments in the pipeline. The
dampener can also be easily removed if needed.
Restrictions on use for Expulse™ dampeners
The dampener temperature and pressure range must not be
exceeded. The temperature ranges are given in Table 2 for
standard hose materials.
The maximum operating pressure for the Expulse™
dampeners is 10 bar (1 MPa). Do not use higher pipeline
pressure than rated for the dampener.
The maximum filling air pressure between outer and inner
hoses is 6 bar (0,6 MPa)
Table 2.
Temperature ranges for Expulse™ dampeners.
Hose material
NR
Min operating temperature (
°
C)
0
Max operating temperature (
°
C)
+95