The MAIN SWITCH must be installed in the immediate vicinity of the appliance,
where it must be easily visible, accessible to the operator and appropriately
marked.
Magnetothermic differential FUSES (slot
≥
3 mm) of appropriate dimensions
must be installed between the electricity network and the MAIN SWITCH.
model
max. current
fuse type
MULTY P 5 TTi (one-phase) 230V/50-60Hz/1ph
32 A
SLOW
MULTY P 7 TTi (one-phase) 230V/50-60Hz/1ph
32 A
SLOW
MULTY P 7 TTI (three-phase) 400V/50-60Hz/3ph
25 A
SLOW
MULTY P 12 TTi (three-phase) 400V/50-60Hz/3ph
32 A
SLOW
MULTY P 12 TTi (three-phase) 230V/50-60Hz/3ph
50 A
SLOW
The position of the MAIN SWITCH with the FUSES in the power circuit scheme
of the appliance:
5 CONNECTING THE APPLIANCE
5.1 INSTRUCTIONS FOR PREVENTION OF INJURIES
When the characteristics of either the water supply or electricity network fail to
meet the requirements for normal operation, the machine must not be
connected to the power supply.
It is forbidden to connect the appliance to the power source when the floor
around the appliance is wet.
It is forbidden to connect the appliance to the power source if any of the side
panels and the cover is missing.
5.2 CONNECTING THE APPLIANCE TO THE WATER SUPPLY
The water supply regulation valve is connected to the WATER SUPPLY PORT.
The water outlet pipe is connected to the WATER OUTLET PORT and to the
outlet pipe leading to the drain. All these terminals have a diameter of 3/4" and
are located on the backside of the machine.
To connect the appliance to the water supply (water supply port) and the outlet
to the drain (water outlet port), use pipes capable of withstanding 1MPa and
measuring at least ½” in diameter (make sure upon the delivery that the pipes
are supplied with the appliance).