MOUNTING ON THE FLOOR
Vallox 245 MV is always mounted on the floor. Adjust the
adjusting legs so that the unit is level.
INS
TALLA
TION
MEASURING AND ADJUSTING THE AIR
FLOWS OF THE VENTILATION UNIT
The accessories delivered with the unit include four (4) air flow
measuring tubes. These can be inserted in the ducts to allow for
easier ventilation adjustment.
WARNING
Water must at all times
be kept out of the
electrical system.
NOTE
When installing the unit,
reserve a space of at
least 800 mm in front
of the unit for servicing
purposes.
REMOVAL OF CONDENSING WATER
NOTE
The Vallox Silent Klick siphon package is delivered with the
unit. Installation instructions for the siphon are enclosed with
the packaging, and can also be found online at www.vallox.
com. To install the siphon, remove the front panel of the base
by undoing the two hexagon screws.