INSTRUCTIONS FOR USE AND MAINTENANCE

Supply / extract ventilation

with heat recovery

for dwellings in blocks of flats

and terraced houses

© VALLOX • We reserve the right to make changes without prior notification.

Содержание TSK Multi 80 MC R

Страница 1: ...LLOX CODE 3468 INSTRUCTIONS FOR USE AND MAINTENANCE Supply extract ventilation with heat recovery for dwellings in blocks of flats and terraced houses VALLOX We reserve the right to make changes witho...

Страница 2: ...t smell fusty when you enter the room in the morning Washing and drying clothes Boost ventilation in washing and drying fa cilities during these activities Taking a sauna bath Boost ventilation in bat...

Страница 3: ...high especially in bedrooms The bathroom and sauna get dry quickly During the heating season the windows and other outer wall structures remain dry Humidity in indoor air is not condensed in the vent...

Страница 4: ...en needed as combustion air for a wood heated sauna oven The resident may regulate the power of ventilation air circulation as needed Filtering Outdoor air is filtered before taking it in to the dwell...

Страница 5: ...ng for example sauna baths cooking clothes washing or family parties If the user does not know the measured air flows the adjacent table shows approximate extract air flows as well as the total electr...

Страница 6: ...ectric box which stops the outdoor air fan in advance The thermostat has been set at the factory to stop the fan when exhaust air temperature goes down to 5 C The fan restarts as soon as exhaust air t...

Страница 7: ...eed for ventilation is fairly small and air is good Speed 3 is used when there is a need for boosting for instance in the following situations cooking taking a sauna bath drying clothes use of toilet...

Страница 8: ...There are four power ranges available Speed 1 Use during absence When the dwelling is empty ventilation can temporarily be diminished Speeds 2 and 3 These are speeds that are normally used Speed 2 is...

Страница 9: ...one when needed preferably at one year intervals depending on local air quality It is recommended to replace filters in autumn This way the filters stay cleaner throughout the winter and can effective...

Страница 10: ...pull the fan out of the unit for maintenance When mounting the fan back make sure that it tightly fits the collar 10 Other cleaning During maintenance also check the general cleanliness of the inner s...

Страница 11: ...ed fan Follow the same instructions as for the cooker hood connected to the ventilation unit For special instructions see the instructions of the cooker hood NOTE It is absolutely forbidden to flamb u...

Страница 12: ...tdoor temperatures check the operation of the antifreeze thermostat The function starts as soon as outdoor temperature goes below 10 C The threshold is not absolute but is dependent on the length of t...