MOUNTING ON A BASE
NOTE
Vallox 145 MV must always be installed on a base on the
floor, or on the wall using a mounting plate.
The base is optional. Adjust the base with adjusting legs to
level it. Remove the (4 pcs) rubber plugs at the bottom of
the unit. Place the unit on top of the base so that the bars of
the base fit in the holes at the bottom of the unit. Mount the
ventilation unit on the wall with a mounting plate, as shown
in the adjacent figure. Make sure that the unit is horizontally
level after mounting.
A Thread bar M8 x 35, shorter thread upward
B The length of the adjusting screw is 37mm.
MEASURING AND ADJUSTING THE AIR
FLOWS OF THE VENTILATION UNIT
The accessories delivered with the unit include four (4) air flow
measuring tubes. These can be inserted in the ducts to allow for
easier ventilation adjustment.
92
1
Ø6
16
NOTE
Mount the ventilation
unit in a place where
the temperature does
not fall below +10°C.