MAINTENANCE

CLEANING THE GREASE FILTER OF THE 
COOKER HOOD

Keep the cooker hood clean. Wipe outer surfaces regularly with 
water containing a small amount of a mild detergent. Clean off 
any grease stains immediately. Do not use abrasive or corrosive 
detergents or tools. 
Keep the grease filter clean to ensure an adequate extract air 
flow. The grease filter must be washed with warm water and 
detergent or in a dishwasher at least 1-2 times a month.

Removing and mounting the grease filter

1.  Pull the locking device of the grease filter towards the front 

edge of the cooker hood while pulling the grease filter 
downwards until it comes off.

2.  Clean the grease filter either by washing it with hot water 

and hand-washing detergent or in a dishwasher.

3.  Mount the grease filter back in place. Push the front edge of 

the filter onto the shelf of the cooker hood and lift the rear 
edge in place with the locking device pressed down.

NOTE! Ensure that the locking device points downwards.

Removing the filter

Mounting the filter

WARNING

Neglecting the cleaning 
of the grease filter can 
cause a fire hazard.

Light

The cooker hood has a long-lasting LED lighting module. If the 
light is not working, contact a servicing company. 

1

2

Содержание 4105063

Страница 1: ...MV Manual Model Vallox 51 MV Vallox 51K MV Type A3750 A3751 Document D7597 Valid from 15 10 2021 Updated 20 12 2021 Ventilation units MANUAL...

Страница 2: ...ard ventilation 15 Adjustment 15 Vallox 51 MV 51K MV 17 Dimensions and duct outlets 17 MAINTENANCE 18 Vallox 51 MV 51K MV 18 Before beginning maintenance work 18 Replacing the filters 18 Cleaning the...

Страница 3: ...te use of the ventilation system or the control unit Incorrect or inappropriate installation setup or use Neglect of instructions concerning transportation installation use or maintenance Structural o...

Страница 4: ...y to country DANGER Indicates a hazard that will result in death or serious injury if not avoided WARNING Indicates a hazard that can result in death or serious injury if not avoided IMPORTANT Indicat...

Страница 5: ...ring service or building automation that uses voltage signals or Modbus messages In addition to the integrated humidity and carbon dioxide sensor ventilation can also be adjusted automatically by usin...

Страница 6: ...Vallox 51K MV The Vallox 51K MV ventilation unit is controlled by using the Vallox Captura cooker hood that is connected to the unit The cooker hood is designed to be used above the cooker top as a ge...

Страница 7: ...on the light close the damper and set the ventilation to the Away mode 2 Press the selection button for roughly 3 seconds until the setting mode signal light starts to flash 3 Adjust the brightness of...

Страница 8: ...L model the parts are mirrored MAIN PARTS Vallox 51 MV Post heating resistor 8 Control panel 9 Internal humidity sensor 10 Internal carbon dioxide sensor 10 Humidity sensor optional 11 Carbon dioxide...

Страница 9: ...the figure In the L model the parts are mirrored MAIN PARTS Vallox 51K MV Internal humidity sensor 10 Internal carbon dioxide sensor 10 Humidity sensor optional 11 Carbon dioxide sensor optional 12 V...

Страница 10: ...s or other frame structure with M8 thread bars so that they withstand the weight of the unit Ensure that the installation plate is horizontally level as this determines the position of the unit Insula...

Страница 11: ...o the area shown in the adjacent figure NOTE Remember to make a service door in the ceiling so that the cables and the connection box can be accessed The distance between the service door and the ceil...

Страница 12: ...NS External electrical connections are led to the ventilation unit through the ceiling bushing for electric wires The length of the wires must enable pulling the fan chamber assembly out of the unit w...

Страница 13: ...llox 51K MV ventilation unit marking the position where the condensing water tube must be installed 1 Install the elbow at the bottom of the ventilation unit without the siphon Figure 1 Install the si...

Страница 14: ...ion unit Push in place Figure 2 3 Ensure that the feedthrough seal of the condensing water tube sits firmly around the tube 4 Lift the front of the cooker hood to fit the mountings into the penetratio...

Страница 15: ...air inside the cooker hood is measured with the damper closed and where required adjusted based on the static pressure loss and the performance scheme of the cooker hood The static pressure loss is m...

Страница 16: ...C Cooker hood extract air D Supply air fan E Extract air fan R model in the figures In the L model the order of the ducts is mirrored C B A B A D E D E Vallox 51K MV Vallox 51 MV INSTALLATION Damper i...

Страница 17: ...4 239 103 81 598 239 155 141 141 143 3 2 1 4 DIMENSIONS AND DUCT OUTLETS 89 173 17 89 598 668 52 349 10 A B 500mm 349 368 597 598 802 668 17 23 23 15 Vallox 51 MV Vallox 51K MV A double socket in thi...

Страница 18: ...r replacement interval depends on the ambient particle concentration It is recommended that the filters be replaced every spring and autumn or at the very least once a year To replace the filters 1 Di...

Страница 19: ...etergent has been added 6 Rinse the cell clean with a water spray Do not use a high pressure cleaner 7 When all the water has drained from between the layers reassemble the ventilation unit in the rev...

Страница 20: ...r from the joint of the damper Turn the crank of the damper motor so that the bar comes off from the bypass damper and turn the damper into the cell bypass position 8 Pull out the upper support of the...

Страница 21: ...ll the locking device of the grease filter towards the front edge of the cooker hood while pulling the grease filter downwards until it comes off 2 Clean the grease filter either by washing it with ho...

Страница 22: ...the Ecodesign Directive 2009 125 EC Southern Finland Helsinki Vantaa TRY year 2012 TECHNICAL SPECIFICATIONS Product title Vallox 51K MV R Vallox 51K MV L Vallox Captura white hood Vallox Captura stain...

Страница 23: ...10 20 30 40 50 60 70 80 90 100 10 20 30 40 50 60 70 80 90 100 Medium frequency of the octave band Hz 63 58 60 62 64 66 68 73 81 81 81 52 52 55 55 59 61 72 70 72 72 125 47 52 57 59 62 65 67 68 68 68 5...

Страница 24: ...ost heating control CO2 Internal carbon dioxide sensor RH Internal humidity sensor R1 Post heating resistor with 90 C and 130 C overheating protection BK Black BU Blue BN Brown WT White GY Grey YE Yel...

Страница 25: ...ATED CLOSED HOUSE AUTOMATION NORMAL SITUATION OPEN ERROR SITUATION HOOD OR VENTILATION UNIT CLOSED ACTIVATED GUARD FUNCTION FLASHING POSITION OF THE DAMPER DAMPER CLOSED CONTACT OPEN DAMPER OPEN CONTA...

Страница 26: ...ytt m n esimerkiksi vikatietoa tai kennon ohituksen tilaa 7037150 2018 09 12 PL KAUKOVALVONTA Modbus RTU Analoginen tulo 2 eri toiminnallisuutta Ulkoinen l mp tila anturi NTC 4K7 RJ45 Naaras 2x0 5 2x...

Страница 27: ...Vallox CO2 sensor MyVallox Control External temperature sensor NTC 4K7 These low current signals can be led by using just one cable RJ45 Female NOTE The ventilation unit has 3 spare feedthroughs Where...

Страница 28: ...sensor connector D I1 Digital input 1 D I2 Digital input 2 11V1 11 1 V operating voltage AN I Analog input 0 10VDC RM I 24V relay input RM O 24V relay output P Circulation pump V Solenoid valve 3x1 5S...

Страница 29: ...tting In winter the duct radiator will turn on when the outdoor temperature falls below the winter setting Manual In summer the duct radiator will turn on when the outdoor temperature rises above the...

Страница 30: ...uded in the delivery The valve that is chosen must be compatible with the heat collection circuit fluid for example Danfoss 032U161431 K Condensing water tube Not included in the delivery IP De aerato...

Страница 31: ...27 933156 14 RJ 45 extension cable 952196 23 Lock nut of the door screw supplied together with the door screw 990715 6 Lower support for HR cell 4103427 15 Internal humidity and carbon dioxide sensor...

Страница 32: ...D power source 940028 6 Lower support for HR cell 4103427 18 MyVallox humidity sensor optional 946149 30 Motherboard 949041 7 Fan chamber assembly R Fan chamber assembly L 4105049 4105048 19 MyVallox...

Страница 33: ...CONFORMITY CERTIFICATES...

Страница 34: ...34 MV...

Страница 35: ...35 Vallox Oy All rights reserved MV...

Страница 36: ...Vallox Oy All rights reserved D7597 20 12 2021FIN 20 12 2021ENG PDF www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND...

Отзывы: