What the units include can vary depending on the sales area.

Adjustment of supply air temperature 

and summer/winter function

The temperature of air coming to the dwelling can be adjusted between circa +10 °C and 

+30 °C. The midpoint of the adjustment range is circa +20 °C. When supply air temperature 

adjustment has been turned in the OFF position, post-heating is not active. This means that 

summer function is activated for the ventilation unit. The unit has a motorised summer/winter 

function. When the summer function is on, the heat recovery cell is bypassed as soon as outdoor 

air temperature has risen above +14 °C. When outdoor air temperature goes below +12 °C, 

the unit starts to recover heat. When supply air temperature adjustment is in the AUTO position, 

automatic function is activated for the unit.  In this case, the setpoint for post-heating is +17 °C 

and the heat recovery cell is bypassed automatically according to outdoor temperatures as 

indicated above. When the unit bypasses the heat recovery cell, in which case summer function 

is activated, post-heating is off.

Fireplace switch function

It is possible to connect a timer-operated switch to the unit. The switch stops the extract air fan 

during the time when the fi replace is heated. NOTE! The starting of the extract air fan may 

weaken draught in the fi replace! In winter, this situation may disturb the winter function of the unit. 

The situation will normalise in a while, after the fi replace function stops.

Winter function of ventilation unit

A threshold value has been set at the factory for the freezing of the heat recovery cell. When the 

threshold is exceeded, the ventilation unit starts to melt the heat recovery cell. Melting is done 

by stopping the supply air fan.
A normal melting period takes from 15 to 45 minutes depending on the extent of ice on the heat 

recovery cell and on the amount of extract air fl ow.
The unit has two different choices for the winter function. One choice is meant for very wet 

conditions (for instance swimming hall) and the other for normal operation in dwellings and 

detached houses.
The factory setting is normal winter function for dwellings and detached houses. 

Adjustment of the relationship between supply and extract air 

This feature may be useful when adjusting air fl ows at the valves during mounting. After the 

valves have been adjusted, a user does not need, and must not, touch the adjustment. When 

needed, supply or extract air fl ow can be reduced at the potentiometer. When the potentiometer 

is approximately halfway, supply and extract air fl ow have not been reduced. Turning the 

potentiometer anticlockwise reduces the air fl ow on the supply side, and turning it clockwise 

reduces the air fl ow on the extract side. 

Maintenance reminder

The unit reminds of the need for maintenance every six months if an indicator (not standard) has 

been connected to the connectors of the fault signal relay. The indicator then blinks at one-second 

intervals. The maintenance reminder is reset when the door of the ventilation unit is opened. See 

the maintenance instructions for information on the necessary maintenance activities.

Fan speed adjustment

The fan speed of Vallox ventilation unit can be controlled with a control switch (option), with 

a separate cooker hood (option) or directly with a 0-10 V voltage signal.
Speeds 1, 2, 3 and 4 can be selected at the control switch:
1.    Operation during absence. When the dwelling is empty, ventilation can be reduced 

temporarily.

2–3. Normal operation. In normal operation, air has to be replaced once every two hours.
4.   Boosted operation. Cooking, taking a sauna bath, washing, drying clothes, using the 

toilet, having guests or a corresponding situation may cause a need for higher ventila-

tion than in normal operation.

OPERATING INSTRUCTIONS

Four-step control switch

(option)

Cooker hood PTXPA-SC

(option)

Adjustment of supply 

air temperature

Supply and extract 

air fl ow adjustment 

potentiometer

Fireplace switch, fl ush 

mounting (option)

This appliance can be used by children 

aged from 8 years and above and 

persons with reduced physical, sensory or 

mental capabilities or lack of experience 

and knowledge if they have been given 

supervision or instruction concerning 

use of the appliance in a safe way and 

understand the hazards involved. 
Children shall not play with the appliance. 
Cleaning and user maintenance shall not 

be made by children without supervision.

Содержание 121 MC Series

Страница 1: ...ch 1 4 option 13 Code 3561 Models VALLOX 121 MC R VALLOX 121 MC L Operating maintenance and technical instructions 10 1 2 3 4 5 6 11 12 8 7 9 Electrical connection 230V 50Hz 5 7A Degree of protection...

Страница 2: ...etached houses The factory setting is normal winter function for dwellings and detached houses Adjustment of the relationship between supply and extract air This feature may be useful when adjusting a...

Страница 3: ...eck the cleanliness of the heat recovery cell D at one year intervals NOTE The laminas of the cell are very thin and get easily damaged The correct way of removing the cell is to put your hands behind...

Страница 4: ...fore the beginning of the heating season make sure that the condensing water outlet L in the bottom tank is not clogged You can check it by pouring a little water in the tank Clean if needed Do not le...

Страница 5: ...DJUSTMENT POSITION AIR FLOW dm3 s Adjustment position 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 2 4 0 5 0 6 0 7 0 8 0 9 0 10 0 11 2 Air flow dm3 s 17 2 29 4 39 8 51 1 65 6 73 1 78 9 91 6 25 2 35 5 44 9 56 3 61...

Страница 6: ...ating PHL Phase voltage to additional heater PHN Zero voltage to additional heater BL Damper motor phase A BL1 Damper motor phase B BN Zero voltage to damper motor E I Input voltage to fault signal re...

Страница 7: ...adily and tightly to the relevant outlets Note Unit models L R Implement duct insulation if needed as defined in the ventilation plan 162 12 21 20 60 20 30 30 20 60 11 20 30 30 11 84 84 35 30 35 7 550...

Страница 8: ...Vallox 121MC VALLOX We reserve the right to make changes without prior notice What the units include can vary depending on the sales area 1 09 420F 14 5 2013 PDF...

Отзывы: