21

© Vallox Oy - All rights reserved

TECHNIC

AL SPECIFIC

ATIONS

FAN INPUT POWER

SUPPLY/EXTRACT AIR VOLUMES

Volume flow rate

Power (W)

Volume flow rate 

(dm

3

/s)

Pressure loss in ducts. Total pressure (Pa)

0

50

100

150

200

250

300

350

0 10 20 30 40 50 60 70 80 90 100 110 120

0 36 72 108 144 180 216 252

m³/h

(l/s)

dm³/s

288 324 360 396 432

L

400

450

130

468

140

504

150

540

160

576

170

612

100 %

80 %

70 %

60 %

50 %

40 %

30 %

20 %

10 %

SFP 1,5 

SFP 1,8 

SFP 1,0 

0

50

100

350

150

300

200

250

0 10 20 30 40 50 60 70 80 90 100

0 36 72 108 144 180 216 252 288 324 360

m³/h

(l/s)

dm³/s

110

396

30 %

50 %

10 %

20 %

40 %

60 %

70 %

80 %

100 %

90 %

130

468

140

504

150

540

160

576

170

612

120

432

Input power (total) (W)

Air flow (max) (dm3/s)

SFP =

SFP rate (Specific Fan Power)

recommended value <1.8 (kW m

3

/s)

extract air

supply air

TECHNICAL SPECIFICATIONS

Product title

Vallox 145 MV R

Vallox 145 MV L

Product number

3475650 

3475750

Air volumes

 

Supply air

 

Extract air

150 dm

3

/s, 100 Pa

155 dm

3

/s, 100 Pa

Fans

 

Supply air

 

Extract air

0,175 kW 1,25 A EC

0,175 kW 1,25 A EC

Post-heating

Electrical resistor, 900 W

Electrical connection

230 V, 50 Hz,  11,9 A power plug

Pre-heating

Enclosure protection class

IP 34

Additional heating

Electrical resistor, 1500 W

Heat recovery bypass

Automatic

Filters

 

Supply air

 

Extract air

ISO Coarse > 75 % + ISO ePM₁

ISO Coarse > 75 % 

Specific energy consumption (SEC)

 

in a cold climate 

 

in a temperate climate

A+

A

Operating efficiencies

 

 

Annual efficiency

 

Supply air efficiency

 

Specific Fan Power (SFP)

75 % A+

85,1 %

0,9 kW (75 dm

3

/s) A

Dimensions

 (w x h x d) 

717 x 748 x 578 mm

Weight

88 kg

Sound power level in the supply air duct (one duct)  

by octave band L

w

, dB

Sound power level in the extract air duct (one duct)  

by octave band L

w

, dB

Adjustment position

Adjustment position

Adjustment position (%)

10

20

30

40

50

60

70

80

90

100

10

20

30

40

50

60

70

80

90

100

Medium

frequency

of the

octave 

band

Hz

63

55

66

73

76

80

83

85

86

87

87

53

58

63

67

73

78

78

79

80

79

125

50

58

64

68

72

76

80

83

84

84

45

50

56

61

65

69

73

75

75

75

250

52

57

63

65

68

72

74

77

78

78

40

39

44

49

54

57

60

63

64

64

500

41

48

53

57

61

64

67

70

71

71

30

37

43

47

50

53

56

58

59

59

1000

53

47

52

57

60

64

65

67

68

68

32

33

36

41

44

48

50

52

53

53

2000

23

34

43

48

53

58

62

64

66

66

15

22

30

34

38

42

45

48

49

49

4000

18

23

36

44

50

55

59

62

63

63

17

17

19

23

27

31

35

38

39

39

8000

21

22

28

39

47

54

58

62

63

63

21

21

21

22

24

28

32

35

36

36

L

W

,dB 

L

WA

, dB(A)

59

68

74

77

81

84

86

88

90

89

54

59

64

68

74

79

79

80

81

81

53

52

58

62

66

69

72

75

76

76

37

40

45

50

54

58

60

63

63

63

Sound pressure level coming through the envelope of the unit in the room in which it is installed (10m² sound absorption)

Adjustment position

Adjustment position (%)

10

20

30

40

50

60

70

80

90

100

L

pA

, dB (A)

28

27

32

35

39

43

46

48

49

49

SOUND VALUES

Содержание 096 MV

Страница 1: ...Manual Model Vallox 096 MV Vallox 110 MV Vallox 145 MV Type A3722 A3702 A3712 Document D5326 Valid from 17 03 2020 Updated 05 02 2020 Ventilation units MANUAL...

Страница 2: ...iphon 10 Space required by the alternative Vallox Silent Klick siphon installation method elbow 10 Vallox 096 MV Vallox 110 MV and Vallox 145 MV 10 Dimensions and duct outlets 11 Vallox 096 MV 11 Vall...

Страница 3: ...odifications or changes made to the software INTENDED USE All Vallox ventilation units have been designed to provide appropriate and continuous ventilation so as to present no threat to health and to...

Страница 4: ...ways be installed on the floor by using a floor rack NOTE The standard equipment and available accessories vary from country to country DANGER Indicates a hazard that will result in death or serious i...

Страница 5: ...lling ventilation remotely also using e g a smartphone or tablet Also the unit software is updated automatically through the cloud service To connect to the cloud service the ventilation unit must be...

Страница 6: ...behind the extract air duct 8 R model in the figure MAIN PARTS Vallox 096 MV Vallox 110 MV and Vallox 145 MV Safety switch 9 Internal humidity sensor 10 Internal carbon dioxide sensor 10 Control pane...

Страница 7: ...the outdoor air and exhaust air duct against condensation also between the unit and the ceiling mounting plate Mounting the ceiling mounting plate 1 Fasten the thread bars on the rafter frames or oth...

Страница 8: ...ection box through the hole in the ceiling mounting plate on top of the ceiling NOTE Remember to make a service door in the ceiling so that the cables and the connection box can be accessed The distan...

Страница 9: ...unit on top of the base so that the bars of the base fit in the holes at the bottom of the unit Mount the ventilation unit on the wall with a mounting plate as shown in the adjacent figure Make sure t...

Страница 10: ...is used the ring seal and the locking part must be moved to the pipe connection part that is mounted on the wall INSTALLATION Dimensioning figure and space required for installation of the Vallox Sil...

Страница 11: ...cell 5 Bypass damper of the HR R model in the figure In the L model the parts are mirrored cell 6 Coarse filter for supply air 7 Coarse filter for extract air 8 Post heating resistor behind the extra...

Страница 12: ...ract air 8 Post heating resistor behind the extract air duct 9 Safety switch 10 Additional heating resistor behind the extract air duct Dimensions and duct outlets Dimensions Duct outlets R model Inne...

Страница 13: ...o the unit L model Inner diameter of the female collar 200mm 1 Exhaust air flowing outdoors from the unit 2 Outdoor air to the unit 3 Supply air from the unit to the apartment 4 Extract air from the a...

Страница 14: ...tration It is recommended that the filters be replaced every spring and autumn or at the very least once a year To replace the filters 1 Disconnect the ventilation unit from the mains electricity supp...

Страница 15: ...ergent has been added 8 Rinse the cell clean with a water spray Do not use a high pressure cleaner 9 When all the water has drained from between the layers reassemble the ventilation unit in the rever...

Страница 16: ...ee chapters Replacing the filters and Cleaning the heat recovery cell 5 Pull out the temperature sensor figure 1 located at the top of the extract air duct G Remove the stopper screw I at the bottom o...

Страница 17: ...gure 9 c Pry the plastic lock to the right of the fan with a screwdriver for example figure 10 d The fan falls downwards e Pull the fan out of the unit figure 11 f Disconnect the fan wire quick connec...

Страница 18: ...5 Open the four screws figure 1 on the extract air fan cover and remove the cover figure 2 The fan can now be cleaned in place 6 To remove the fan for cleaning a Push the fan gently upward figure 3 b...

Страница 19: ...ate climate A A Operating efficiencies Annual efficiency Supply air efficiency Specific Fan Power SFP 75 A 85 7 1 0 kW 38 dm3 s B Dimensions w x h x d 600 x 545 x 428 mm Weight 53 kg Sound power level...

Страница 20: ...in a temperate climate A A Operating efficiencies Annual efficiency Supply air efficiency Specific Fan Power SFP 75 A 85 7 0 9 kW 38 dm3 s A Dimensions w x h x d 638 x 678 x 472 mm Weight 64 kg Sound...

Страница 21: ...SO Coarse 75 Specific energy consumption SEC in a cold climate in a temperate climate A A Operating efficiencies Annual efficiency Supply air efficiency Specific Fan Power SFP 75 A 85 1 0 9 kW 75 dm3...

Страница 22: ..._B Local hardware Modbus B signal NTC External temperature sensor connector D I1 Digital input 1 D I2 Digital input 2 11V1 11 1 V operating voltage AN I Analog input 0 10VDC RM I 24V relay input RM O...

Страница 23: ...r fan tacho WT 5 GND GN 6 Supply air fan PWM YE C 1 Extract air 2 Outdoor air 3 Supply air 4 Exhaust air 5 Supply air from the HR cell D LAN MB_A External Modbus A signal MB_B External Modbus B signal...

Страница 24: ...ut EXTERNAL ELECTRICAL CONNECTION 3x1 5S 2x2x0 5 0 5 2x0 5 2x0 5 7028350 2014 08 29 JS 2x2x0 5 0 5 2x0 5 2x2x0 5 0 5 2x2x0 5 0 5 2x2x0 5 0 5 2x0 5 2x0 5 CAT Analog input two different functions Potent...

Страница 25: ...r NTC 4K7 MB_A External Modbus A signal MB_B External Modbus B signal 24V 24V voltage DC GND Digital and analog ground potential RS_A Local hardware Modbus A signal RS_B Local hardware Modbus B signal...

Страница 26: ...the supply air temperature will be maintained at the level specified in the temperature setting In winter the duct radiator will turn on when the outdoor temperature falls below the winter setting Ma...

Страница 27: ...ve Not included in the delivery The valve that is chosen must be compatible with the heat collection circuit fluid for example ELV05006 Stig Wahlstr m K Condensing water tube Not included in the deliv...

Страница 28: ...22 NTC sensor kit 3480500 5 Coarse filter for supply air 978044 13 Extract air outlet 985026 23 Glass tube fuse 63mA slow 5x20mm 952490 6 Fine filter for supply air 978220 14 Internal humidity and ca...

Страница 29: ...filter for supply air 978157 15 Internal humidity and carbon dioxide sensor 4107982 24 NTC sensor kit 3457900 7 Lower support for HR cell 3450100 16 Motherboard 949032 1 25 Glass tube fuse 63mA slow...

Страница 30: ...24 NTC sensor kit 3482300 7 Lower support for HR cell 3469000 16 Motherboard 949032 1 25 Glass tube fuse 63mA slow 5x20mm 952490 8 HR cell 933270 17 Safety switch 948377 26 MyVallox Control panel 949...

Страница 31: ...CONFORMITY CERTIFICATES...

Страница 32: ...D5326 04 02 2020FIN 05 02 2020ENG PDF www vallox com Vallox Oy Myllykyl ntie 9 11 32200 LOIMAA FINLAND Customer service 358 10 7732 200 Aftersales 358 10 7732 270...

Отзывы: