background image

8

TECHNIC

AL SPECIFIC

ATIONS

600

545

583

38

L model

Inner diameter of the female collar: 125mm

1.  Exhaust air out

2.  Outdoor air to the unit

3.  Supply air to the apartment

4.  Extract air from the apartment to the unit

R model

Inner diameter of the female collar: ø125mm

1.  Supply air to the apartment

2.  Extract air from the apartment to the unit

3.  Exhaust air out

4.  Outdoor air to the unit  

93

102

298

363

600

141

459

407

430

1

4

2

3

Air flow measurement points

Measurement points after the outlet collar. The fan curves 

indicate the total pressure accounted for by duct losses.

Supply air

Extract air

TECHNICAL SPECIFICATIONS 

Nimike

 

Vallox 096 MC R

 

Vallox 096 MC L

Product number

3474600

3474700

Air volumes  Supply air

 

 

Extract air

92 dm3/s, 100 Pa

95 dm3/s, 100 Pa

Electrical connection

230 V, 50 Hz, 5.1 A power plug

Enclosure protection class

IP 34

Post-heating

Electrical resistor, 900 W

Pre-heating

Additional heating

Fans  

Supply air

 

 

Extract air

0,119 kW 0,9 A EC

0,119 kW 0,9 A EC

Specifi c energy consumption (SEC)

 

 

in a cold climate

 

 

in a temperate climate

A+

B

Operating effi  ciencies   

 

 

 

Annual effi  ciency

 

 

Supply air effi  ciency

 

 

Specifi c Fan Power (SFP)  

75% A+

85.7%

1.0 kW (38 dm3/s) B

Filters 

Supply air

 

 

Extract air

ISO Coarse > 75 % + ISO ePM₁

ISO Coarse > 75 %

 

Heat recovery bypass

Automatic

Dimensions

 

(w x h x d) and weight

600 x 545 x 428 | 53 kg

DIMENSIONS AND DUCT 

OUTLETS

Duct outlets

Dimensions

Содержание 096 MC L

Страница 1: ...Manual MANUAL Ventilation unit Document D2609 Valid from 24 02 2017 Updated 07 04 2020 Model Vallox 096 MC R Vallox 096 MC L Type 3721 1...

Страница 2: ...l panel ordered separately Vallox ProControl panel ordered separately Vallox Capto PTC EC control hood Vallox X Line PTXP MC control hood or Vallox X Line PTXPA MC control hood or dered separately 6 1...

Страница 3: ...is in the summer mode i e post heating is turned off and the heat recovery cell is bypassed when the outdoor temperature is above 14 C The heat recovery will be turned on when the outdoor temperature...

Страница 4: ...the outdoor air is faulty Check the sensor and the wires replace as required 6 The supply air fan has stopped Check the wiring of the fan replace the fan as required 7 The extract air fan has stopped...

Страница 5: ...unit and the best filtering results The filter replacement interval depends on the ambient dust concentration It is recommended that the filters be replaced every spring and autumn or at the very lea...

Страница 6: ...from the bottom edge of the duct The extract air duct can now be removed by simultaneously turning and pushing it downwards figures 2 and 3 Remove the temperature sensor from the resistance support fi...

Страница 7: ...ver figure 6 This will make the fan fall downwards Pull the fan out of the unit figure 10 Disconnect the quick connector of the fan cables F P 8 10 9 CONDENSING WATER In the heating season the extract...

Страница 8: ...ct air TECHNICAL SPECIFICATIONS Nimike Vallox 096 MC R Vallox 096 MC L Product number 3474600 3474700 Air volumes Supply air Extract air 92 dm3 s 100 Pa 95 dm3 s 100 Pa Electrical connection 230 V 50...

Страница 9: ...dB LWA dB A 57 61 65 68 71 74 76 78 79 79 52 56 64 66 71 74 76 79 80 80 34 39 44 47 51 54 56 59 60 60 33 39 45 48 52 55 58 61 63 63 Sound pressure level coming through the envelope of the unit in the...

Страница 10: ...Vdc 1 Control signal S DIP switch 1 Post heating 2 Additional heating 3 Type of the unit 4 Extra Up Electric Electric Bypass Down VKL MLV Supply fan stop An external 0 10 V DC voltage supply can be co...

Страница 11: ...GND S GND S MC VENTILATION UNIT Four terminal connector MV VENTILATION UNIT GND AN I RM I RM O E I LED E O PROGRAMMING CONNECTORS OF THE MOTHERBOARD CONTACT DATA GUARD FUNCTION NORMAL SITUATION OPEN A...

Страница 12: ...5 Common RH optional 946147 Nomak 2x2x0 5 0 5 0 10 V LED G G0 Y1 Y2 DI1 A1 Y3 A2 Y4 U1 A B C S DI2 G0 Vallox ProControl 949034 S LED S B term CONFIG Control signal S Cooker hood or boost switch 11 2 V...

Страница 13: ...10 mm higher than the final height 433 The minimum distance between the top of the unit and the finished ceiling surface is 30 mm The outer diameter of the duct is 12mm 162 12 21 20 60 2030 30 20 60...

Страница 14: ...he mounting supplies delivered with the mounting plate Note The end of the thread bars must be 5mm or less below the fastening nut more detailed instructions are provided with the ceiling mounting pla...

Страница 15: ...method requires that there is a 47mm space underneath the unit The elbow requires a 38mm space when installed 5 395 8 15 15 630 5 395 8 15 15 630 5 395 8 15 15 630 Attic floor penetration plate option...

Страница 16: ...plate 3080700 4 Siphon Vallox Silent Klick 3292500 5 Coarse filter for supply air 978044 6 Fine filter for supply air 978220 7 HR cell 933260 8 Upper support for HR cell 3467200 9 Filter stand extract...

Отзывы: