VALLEY FORGE & BOLT SPC4 406A Скачать руководство пользователя страница 7

 

 

SPC4™ SYSTEM • MODEL 406A • USER’S MANUAL   

Rev. 1.0 

 

 

- Page 5 of 23 - 

1.0.0

 

Introduction 

The SPC4™ Model 406A Load Monitoring System (SPC4™ System) is designed to measure SPC4™ 

fastener tension in real-time and display the load data as a percentage of minimum yield on the 

406A’s LCD or employ the Bluetooth 2.0 capability for remote clamp load monitoring from a smart 

device.. There are several uses for the 406A Load Monitoring System: 

1.

 

During fastener installation, the SPC4™ 406A will confirm that the fastener has reached 

desired proper clamp load.  

2.

 

During a flange installation, the SPC4™ 406A can be used to check how SPC4™ fasteners 

react as load is being distributed among the installed fasteners.  

3.

 

During maintenance inspections, the SPC4™ 406A can be used to verify load on each 

SPC4™ fastener to determine if it needs to be retightened. 

The SPC4™ System contains precision electronic devices. Care must be taken in handling all its 

components.  Abusive handling of these components or devices can render them inoperable 

and/or compromise the accuracy of the measured load readings.  
All SPC4™ load indicating fasteners have been shipped with protective caps installed over the 

datum discs to protect and maintain surface cleanliness. These protective caps must remain on 

the datum disc, only to be removed during use of the SPC4™ 406A unit.   
Valley Forge & Bolt Manufacturing Company assumes no responsibility for inaccurate loading or 

failure of SPC4™ load indicating fasteners as a result of damage to the measuring instrument 

caused by improper handling or improper maintenance of datum disc surfaces. With proper care 

and use, this system will provide years of reliable operation.  
This manual includes critical information on the components, operation, and maintenance of the 

SPC4™ System. It is 

imperative

 to read this manual carefully and completely familiarize yourself 

with the operation of this system before use.  

1.1.0

 

Inspection 

When unpacking the SPC4™ System, carefully check each item for damage that may have 

occurred during shipment. If anything is damaged or missing contact: 

VALLEY FORGE & BOLT MANUFACTURING COMPANY 

4410 West Jefferson Street ● Phoenix, AZ 85043 ● USA

 

Phone: (602) 269 - 

5748 ● Fax: (602) 269 

- 7851  

E-

mail: [email protected] ● Web: www.vfbolts.com 

 

1.2.0

 

Included Items 

SPC4™ Model 406A Load Monitoring System (406A unit)

 

406A unit 

User’s Manual (this manual) 

UM 

Calibration Gage (0% & 100%) 

CG 

Brass Bristle Brush 

BBB 

Carrying Case 

CC 

3

 

AA Batteries 

AA 

Helper Tool  

HT 

 

 

Содержание SPC4 406A

Страница 1: ...SA WEB www vfbolts com VALLEY FORGE BOLT MANUFACTURING COMPANY 4410 W Jefferson St Phoenix AZ 85043 USA Phone 602 269 5748 Fax 602 269 7851 E mail sales vfbolts com Web www vfbolts com SPC4 MODEL 406A...

Страница 2: ......

Страница 3: ...e However the term is more often applied to installation than to the service life of the bolted joint Valley Forge Bolt s family of load indicating fasteners makes it possible to monitor bolted joints...

Страница 4: ...VALLEY FORGE BOLT MANUFACTURING COMPANY PHONE 602 269 5748 4410 W Jefferson St Phoenix AZ 85043 USA WEB www vfbolts com SPC4 SYSTEM MODEL 406A USER S MANUAL Rev 1 0 Page 2 of 21...

Страница 5: ...USER S MANUAL Rev 1 0 Page 3 of 21 This device contains FCC ID 2ADMF HC06 RF module that complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 this device may n...

Страница 6: ...3 4 406A Unit Rear View Image 9 1 3 5 Calibration Gage CG 10 1 3 6 Brass Bristle Brush BBB 10 1 3 7 Carrying Case CC 10 1 3 8 AA Batteries AA 11 1 3 9 Helper Tool HT 11 2 0 0 SPC4 406A Operation 12 2...

Страница 7: ...rotective caps installed over the datum discs to protect and maintain surface cleanliness These protective caps must remain on the datum disc only to be removed during use of the SPC4 406A unit Valley...

Страница 8: ...be continuously red when there is an active Bluetooth connection to another device 2 LIQUID CRYSTAL DISPLAY LCD The LCD contains useful information regarding the status of the meter and displays the...

Страница 9: ...602 269 5748 4410 W Jefferson St Phoenix AZ 85043 USA WEB www vfbolts com SPC4 SYSTEM MODEL 406A USER S MANUAL Rev 1 0 Page 7 of 21 1 3 2 406A Unit Top View Image Figure 1 406A Unit Top View 1 LINK LE...

Страница 10: ...value and should be used in conjunction with the 0 end of the calibration gage supplied with this unit 7 GAIN ADJUSTMENT A dial used in calibrating the 406A unit This dial is used to adjust the calibr...

Страница 11: ...hoenix AZ 85043 USA WEB www vfbolts com SPC4 SYSTEM MODEL 406A USER S MANUAL Rev 1 0 Page 9 of 21 1 3 4 406A Unit Rear View Image Figure 2 406A Rear View 4 BATTERY COMPARTMENT 5 ENCLOSURE SCREWS 6 OFF...

Страница 12: ...he end marked 100 the 406A unit will display a load value of 100 5 between 95 095 and 105 105 1 3 6 Brass Bristle Brush BBB Figure 4 Brass Bristle Brush BBB The brass bristle brush see Figure 4 Brass...

Страница 13: ...e a 406A battery Battery life can be extended by using good practices such as turning off the Bluetooth when not in use We recommend using non rechargeable AA Lithium batteries to further extend the b...

Страница 14: ...aking measurements See 2 3 0 Using the 406A Bluetooth if a Bluetooth connection will be used 2 Turn on the 406A unit by momentarily pressing the ON OFF button The 406A will begin the boot up sequence...

Страница 15: ...ing 5 Remove the protective cap from the fastener and verify that the datum disc and 406A probe sensor are clean of any liquid or debris See 4 0 0 User Maintenance Recommended Cleaning Procedures 6 Re...

Страница 16: ...e clips hold onto the batteries tightly so some feel will be required 4 Dispose of the old batteries 5 Install fresh batteries into the 406A unit following the positive and negative lead indications T...

Страница 17: ...serial monitor app open establish a connection to the SPC4_M406A Tweak the Bluetooth data settings to match the Bluetooth settings found in 3 1 0 Electrical Specifications 11 Data can now be monitored...

Страница 18: ...on gage several times to ensure the integrity of the 100 reading which verifies that the 100 measurement has been calibrated correctly 4 It may be necessary to perform the calibration check multiple t...

Страница 19: ...tocol Bluetooth Version 2 0 SPP Serial Port Profile Wireless Data Format Serial 9600 baud 8N1 Pairing Code 4410 Display Type 3 1 2 Digit Reflective LCD 12 7 mm 0 50 in Digit Height Viewing Area W x H...

Страница 20: ...d solution of warm water and detergent 3 Any attempts to clean the 406A unit should be made in the OFF power state while the enclosure lid is tightened on 4 DO NOT ATTEMPT TO CLEAN THE INSIDE OF THE E...

Страница 21: ...eter install meter on unloaded fastener to check 0 reading 2 If meter is not reading 0 follow these steps then refer to 5 0 0 Troubleshooting a Ensure mating parts are clean datum disc and probe b Re...

Страница 22: ...tment to visually inspect the battery connections 2 Remember to close the battery compartment afterwards 3 Check the cleanliness of the probe sensor and SPC4 fastener datum disc 1 Inspect probe sensor...

Страница 23: ...ay accumulate after repeated use These deposits usually result in erratic and inconsistent load readings 5 The metallic chips can become lodged into the insulator surfaces In most of the cases these w...

Страница 24: ...VALLEY FORGE BOLT MANUFACTURING COMPANY 4410 W Jefferson St Phoenix AZ 85043 USA Phone 602 269 5748 Fax 602 269 7851 E mail sales vfbolts com Web www vfbolts com...

Отзывы: