- 8 -
g
!
!
WARNING! Connection to the power supply
network must be made with a 230V~50Hz
socket with an earthed contact. See attached
technical data.
MACHINE DESCRIPTION (FIG.A)
1 Pump body
2 Coupling handle
3 Pump base with liquid suction
4 Delivery
5 Starting float
6 Power supply cable
7 Technical data label
8 Suction grid
SYMBOLS (FIG.B)
1 Technical data
2 Double electric insulation
3 CE conformity mark
FIELD OF USE OF THE PUMP
High head multi-stage pump for clear water.
The submersible pump is suitable for suction
exclusively water where it is possible to im-
merse directly. It can be used in wells, tanks,
containers, etc. where there is no direct con-
tact between people and water (it should not
be used in swimming pools and similar, unless
otherwise indicated). The pump, by means of
the float switch, starts and stops automatically
depending on the water level.
It is only suitable for clean water.
It is a high-pressure pump, see the following
technical data and indications.
CONNECTION TO THE ELECTRIC POWER
SUPPLY
The pump is equipped with a connection cable
and plug. Connect the plug to a appropriate
socket which must be equipped with an efficient
earthed contact.
Check that the socket is efficient and that it has a
protection device for over currents of at least 6 A.
WARNING! Always check that the cable
and the plug are not damaged. Do not use the
pump if the cable is damaged!
!
!
If the power cable is damaged, it must be
replaced by the manufacturer, support service
or qualified staff in order to avoid any dangers.
!
!
WARNING! Installation Standards
- Always observe the values of ‘maximum immer-
sion depth’ and ‘maximum head’ shown in the
specifications.
- Do not transport aggressive liquids or liquids with
abrasive substances in a suspension.
- Protect the pump from freezing.
- Do not operate the pump dry.
- Never hang up the pump by its water delivery
hose, by the power supply cable or by the float.
- The pump must be resting on its base or
hanging up using the special handle, always
upright.
- In order to guarantee optimal operation of the
pump, the bottom of the sump must be clean
and free from mud. The mud could block the
impeller when it dries inside, stopping the
pump from working.
- Do not use the power cord for lifting and tran-
sporting the pump.
- The plug should not be submerged.
- Remove the power from the pump and di-
sconnect any possible plug from the mains
before any maintenance, cleaning or moving
operation.
- Use protective gloves for each operation on
the pump.
INSTALLATION
- Screw the connection onto the pump delivery
(pos. 4).
- Fix the delivery hose onto the rubber holder.
WARNING! The outlet pressure of the pump is
high, use a suitable hose and clamp.
- Immerse the pump in the liquid to draw using
a rope tied to the handle.
- The power cord must be immersed for sud-
denly only necessary but not too tense.
WARNING! Always check that the power cord
does not interfere with the movement of the
float.
- Connect the power supply cable to the socket.
The float switch allows the pump to be started
and stopped automatically according to the