The following general procedures
must be observed in relation to the
location and installation of System
One Home Communication
components:

Stations are not to be installed
“back to back” or in “line of
sight” of each other as this will
cause feed-back (squealing).

Where stations are to be fitted
externally, appropriate
measures to provide protection
from weather are to be taken.

Avoid running Intercom cable
in parallel to electrical wiring.

The Power supply is not to be
installed in a cavity wall or any
area (roof etc) where
temperatures are likely exceed
100°F.

Guidelines for maximum cable
lengths as set out in this
manual are to be observed to
avoid the possibility of
operating problems due to
excessive voltage drop.

The maximum number of
stations on a system including
Master, Room and Door
stations is generally limited to
20. It is important that the
power supply is properly
matched to the size
of the system. (See Power
Supply on pg 8)

CAUTION:

Failure to use

specified cable may cause
problems with the performance of
the system and will void warranty on
the equipment.

IMPORTANT:

Responsibility will not

be taken for problems that arise
from the improper use of cable or
interference generated externally
to the system.

Interference by light dimmers,
fluorescent lighting and similar
electrical products, must be
corrected at the source.

An aid to reducing the effects of this
type of interference is to place
stations and wiring no closer than
30cm (12”) from any AC device or
wiring.

The circuitry of the intercom has
been designed to minimize the
effects of Radio Frequency
Interference however total
immunity to this type of interference
cannot be guaranteed where the
levels of interference generated are
extreme.

GENERAL INFORMATION

POS  - 15 VDC  (RED)
May measure from 13.8V to 15.5 VDC with respect to 0V depending on voltage
drop due to cable length.

NEG - 0 VDC  (BLACK)

TC - TIMER CONTROL (SHIELDED RED)
Holds receiving stations on line for period controlled by initiating station.
Normally low. Goes high when chime activated or call initiated from any station.
Stays high until chime or call is reset.

VLC - VOLTAGE LEVEL CONTROL  (SHIELDED WHITE)
Carries different voltage levels generated by initiating station to allow targeting
of calls etc. Voltage is present for duration of button press or chime activation.

COMMUNICATION LINES - COM1 (WHITE) & COM2 (BLUE)
Carries balanced audio signal for Chimes, Private Calls &  Paging Calls.

MUSIC/ MONITOR LINES  -  MUS1 (GREEN) & MUS2 (ORANGE)
Carries balanced audio signal for Music and Monitoring

.

AUX - AUXILIARY OUTPUT CONTROL (SINGLE CORE)
Carries different voltage levels generated at initiating station, to control specific
outputs on Auxiliary Output boards.

NOTE:

Shielded cable recommended for TC and VLC Lines to prevent
spikes caused by rising and falling control signals being induced
onto audio lines.

CABLE FUNCTIONS

Содержание System One MINI

Страница 1: ...Intercom Installation Guide Distributed by Lindsay Manufacturing Inc www vacumaid com 1 800 546 3729 L6237 ...

Страница 2: ...5 WHAT CABLE TO USE 5 MAXIMUM LENGTH FOR CABLE RUNS 6 INSTALLATION OF SYSTEM ONE MINI 8 11 INSTALLATION OF DOOR GATE STATIONS 12 INSTALLATION OF AUXILIARY INPUT JACK 12 POWER SUPPLY 8 WIRING DIAGRAM 10 CONTROL VOLTAGE LOAD RESISTOR 10 PROGRAMMING ROOM STATIONS 13 KEYPAD BACKLIGHTING 14 DOOR STATION ADJUSTMENTS 14 CHANGING THE CHIME 15 CHIME VOLTAGE OUTPUT 15 SIX WIRE OPERATION USING ROOM STATIONS ...

Страница 3: ...rected at the source An aid to reducing the effects of this type of interference is to place stations and wiring no closer than 30cm 12 from any AC device or wiring The circuitry of the intercom has been designed to minimize the effects of Radio Frequency Interference however total immunity to this type of interference cannot be guaranteed where the levels of interference generated are extreme GEN...

Страница 4: ...ot more than 16 ft from the point of connection at the master or from the point of connection at a room station if a master has not been fitted installed prior to lining tiling of the walls and the tiles will need to be cut to the inside dimensions of the wall box Where room stations are mounted outside and are exposed to the weather the fitting of weather proof covers will be required Stations mu...

Страница 5: ...cuits etc to be controlled from the Master or any Room station There are two 2 outputs on each board which can individually be programmed to time out or toggle depending on the application Four 4 of these boards can be fitted to any one system allowing a total of eight 8 Auxiliary outputs in total Each board is fitted in conjunction with a room station and is located in the side compartment of the...

Страница 6: ...tail provided or a car radio antenna must be plugged into the socket at the end of the cable The plug at the master end of the cable must be cut off Additional AM coax leads can be plugged into one another if additional length is required Exit program mode by pressing the CANCEL CLEAR button Note Single and Double Digit format cannot be mixed in one system Each station is to be individually progra...

Страница 7: ...efault number being 1 Press the AUX button to toggle to Double Digit Mode In Double Digit mode the red LED will repeatedly flash the following information Two quick flashes representing Double Digit Mode One to three flashes representing the first digit default 1 One to eight flashes representing the second digit default 1 Enter a double digit number in the ranges of 11 to 18 21 to 28 31 to 38 24 ...

Страница 8: ...f cover should be fitted Green and orange wires are not used at door station Tape green and orange wires back to white outer sheath of valet cable Do not connect green and orange wires of door station cable at room station end Tape back in same manner as above Where a door station is part of a wiring loop the door station should always be the last station on the loop INSTALLATION OF DOOR STATIONS ...

Страница 9: ... stations connected A system using a 12V 6 5AH battery with ten stations connected to a master will run for approximately 3 hrs with music playing at a moderately high volume 6 hrs w music off POWER SUPPLY Multiple Supplies Multiple power supplies may be used to provide additional current however their output voltages need to be identical to minimize power losses Connect the Terminal block The Ter...

Страница 10: ...6 washer behind the screw This allows for 1 16 adjustment for proper leveling Fig 2 Bend the Tabs The metal mounting bracket has 8 tabs along the interior perimeter of the bracket Once the bracket has been securely fastened to the 3 gang box these 8 tabs will need to be bent 90 into the 3 gang box opening Fig 3 These tabs are for use in a retro fit application 2 Fig 2 3 Fig 3 The fitting of a Load...

Отзывы: