BUS BODY ELECTRONICS

 

 

 
 

SC1000 OTOKAR 

 

 

Operating Instructions 
– Bus Driver 

 

 

Содержание SC1000 OTOKAR

Страница 1: ...Rev 07 06 2019 Id No DOK31016 BUS BODY ELECTRONICS SC1000 OTOKAR Operating Instructions Bus Driver...

Страница 2: ...3 Adjust air flow direction defrost function 9 2 3 4 Toggle between fresh air and air recirculation 10 2 4 Passenger compartment functions 10 2 4 1 AUTO mode 10 2 4 2 Adjust blower speed level 11 2 4...

Страница 3: ...UTO Mode OFF 11 Figure 13 SC1000 Manual Blower Speed Level 11 Figure 14 SC1000 Current Room Temperature 12 Figure 15 SC1000 Current Exterior Temperature 12 Figure 14 SC1000 Air Recirculation Mode Acti...

Страница 4: ...f top air conditioning systems heaters etc It comprises always of a control panel control device with human to machine interface which is integrated into the dashboard and of one or more substations w...

Страница 5: ...BUS BODY ELECTRONICS 4 A substation is a control device with power outputs for the control of all the components inte grated in the AC unit Figure 2 SC1000 Substation...

Страница 6: ...BUS BODY ELECTRONICS 5 1 2 Symbols used Note...

Страница 7: ...Fresh air air recirculation but ton 5 Fresh air air recirculation button optional 9 Reheat dehumidify button optional 2 Air direction control 6 Blower speed button optional 10 AUTO mode button 3 Blow...

Страница 8: ...ompartment L Air recirculation is on HVAC version only D Time M Is indicated with the current room tem perature E Blower speed level N Is indicated with the current outside temperature F Error icon O...

Страница 9: ...ig 6 2 2 Turn OFF Switch off the ignition The system powers down 2 3 Driver s workplace functions 2 3 1 Adjust Temperature 2 3 1 1 Cooling if the roof top air conditioning unit is in cooling mode only...

Страница 10: ...r flow direction Rotate knob Fig 3 No 2 counterclockwise into 7 o clock position air flow onto the floor Rotate knob clockwise into 12 o clock position air flow against the wind screen and the floor R...

Страница 11: ...to the fresh air air recirculation button lights up 2 4 Passenger compartment functions 2 4 1 AUTO mode 2 4 1 1 Activate Press button Fig 3 No 10 shortly Mode is activated the LED next to the button...

Страница 12: ...ed the compressor and the heating are off The blower speed is automatic unless it has been manually set Note The blower can be set from 10 to 100 in steps of 10 10 is the smallest blower speed on leve...

Страница 13: ...mperature Press button Temperature 1 C Press button Temperature 1 C 2 4 3 2 Display the current room or outside temperature Press button INT and the current room temperature are shown on the dis play...

Страница 14: ...recirculation icon Fig 14 appears on the display Press the button when the manual operation of the fresh air flaps is active The fresh air flaps are operated automatically again The LED next to the bu...

Страница 15: ...is the responsibility of the driver He must ensure that at the start time the circumstances and the parking situation are suitable For security reasons it is only possible to program the timer for th...

Страница 16: ...the screen Fig 22 2 5 3 1 Choose start time Press button to display the memory locations PrE1 appears on the display Fig 23 Press buttons to scroll through memory locations PrE1 7 and select one of t...

Страница 17: ...We Th Sa Su using the buttons Press button to confirm the day 0 appears on the screen Fig 26 2 5 3 2 Set operation time Press buttons to set operating time Press button to confirm operating time 2 5 3...

Страница 18: ...s on the screen Note The reheat mode can only be activated in the AUTO mode when the engine is running and at at least 8 C outside temperature In addition the difference between setpoint of room tempe...

Страница 19: ...ers s seat until the standard screen appears 2 7 1 4 Erase error Press the button 6 seconds The error stops being displayed If the error has not been corrected it appears again with a dot between the...

Страница 20: ...tion is inter rupted substation 1 1 Verify the substation is active Check plug connections Replace substations Replace control unit 12 Hot water valve has failed roof sub station 1 1 Check plug connec...

Страница 21: ...ck whether B1 occurred if this is the case see B1 2 Short term overload of the airconditioning sys tem due to high engine speed at high ambient temperature The air conditioning system turns off for th...

Страница 22: ...t be performed Examine the roof top airconditioning unit for soil ing and check the function of the fans Replace substation B2 Ice formation at the evaporator Temporary shutdown of the airconditioning...

Страница 23: ...ial Vehicles Germany GmbH Friedrichshafener Str 7 82205 Gilching Germany Tel 49 0 8105 7721 0 Fax 49 0 8105 7721 889 www valeo thermalbus com service valeobus valeo com Valeo Thermal Commercial Vehicl...