Preparation for installation

 

 

 

2.  Preparation for installation 

2.1.  Safety instructions 

  The safety instructions outlined on pages 3 and 4 must be read 

and noted before starting work. 

  Installation should be performed by someone well versed in auto 

mechanics/auto electrics. 

2.2.  Conditions for assembly 

  Before assembling and operating the air-conditioning system(s), 

the vehicle's power supply must be checked for sufficient capacity, 

and must be upgraded if necessary. 

  A free generator capacity of 65 A (max. current consumption per 

unit) must be at disposal per unit to be constructed. This capacity 

must be guaranteed at idle speed, and at the same time at 

maximum engine compartment temperature (low speed and high 

ambient temperature diminish the output of generators). 

 

 

 

 

 

 

2.3.  Preparations on vehicle’s roof 

 

When working on the bus roof or on any hoisting equipment, 

scaffolding etc. suitable safety precautions must be taken to 

prevent falls. 

 

Wear protective gloves! 

2.4.  Roof cut-outs 

The required roof cut-outs (opening for refrigerant connection and 

electrical interfacing) must be clearly indicated on the roof. Make 

the roof cut-out using suitable tools. Cut edges should be deburred 

and protected against corrosion. 

NOTE: 

Interface drawings can be obtained from Spheros! 

Warning! 

Danger of severe injuries or 

fatal fall! 

Caution! 

Danger of cut injuries due to 

sharp metal edges! 

Содержание Citysphere S

Страница 1: ...CITYSPHERE S Standard Installation instructions Rev 06 2014 Id No 11120621A AIR CONDITIONING...

Страница 2: ...ing the vehicle s roof and the AC unit 7 3 Mounting the air conditioning unit 8 3 1 Applying the adhesive 8 3 2 Position the air conditioning unit 9 3 3 Fastening the unit 9 4 Connecting the air condi...

Страница 3: ...stallation manual and its included notes will lead to liability exclusion by Spheros The same applies to unskilled repairs or repairs not using original spare parts Electrical wiring and operating ele...

Страница 4: ...must be carried out by duly qualified personnel Such work may only be undertaken with the engine off and the power supply switched off The battery must be disconnected before starting the work Do not...

Страница 5: ...ted This capacity must be guaranteed at idle speed and at the same time at maximum engine compartment temperature low speed and high ambient temperature diminish the output of generators 2 3 Preparati...

Страница 6: ...icle s shell with nuts M8 and matching washers For this purpose corresponding stable retaining plates bows must be provided on the shell We suggest making the drill holes sufficiently large or long to...

Страница 7: ...roof the areas must be cleaned with compressed air Roughen bonding area of the base pan and the roof surface according to the adhesive joint clean with Sika Cleaner and preprocess with Sika Primer fo...

Страница 8: ...ning unit and the vehicle s roof is to apply the adhesive material onto the base pan when the AC unit is lying Apply the Sika bead all round along the screws and support points min thickness 10mm Make...

Страница 9: ...ing unit onto the roof and insert the fastening bolts through the drill holes on the roof Follow pro cessing time prescribed by the manufacturer of the adhesive material 3 3 Fastening the unit Fix all...

Страница 10: ...e holder The refrigerant piping and shut off valves Item 1 2 in the vehicle must be provided for thermal reasons and to prevent condensation with an insulation Recommendation Suction and pressure line...

Страница 11: ...Power supply must be uninterruptible Connect system directly to the battery Connecting bolt Connecting plate G1 Ground connector bolt Connecting plate G2 Signal ON max 5A fuse must be used 3 5A fuse...

Страница 12: ...ed Evacuate the front box inclusive the piping Ensure the system is leak proof Then open system valves The unit is pre filled with 1 1 kg refrigerant R134a amount of refrigerant is designed for a max...

Страница 13: ...ecked for continuity The following possibilities must always be checked and excluded as a possible cause of the malfunction Defective fuses Corrosion of plug contacts Loose contact in plug connectors...

Страница 14: ...memos...

Страница 15: ...Valeo Thermal Commercial Vehicles Germany GmbH Postfach 1371 82198 Gilching Germany Tel 49 0 8105 7721 0 Fax 49 0 8105 7721 889 www valeo thermalbus com service valeobus valeo com...

Отзывы: