OPERATING THE AIR CONDITIONER

1.3- Off Mode

1.4- Automatic Mode

1.4.1- Automatic Ventilation

1

2

3

4

The controller can be started by the ON/OFF key or through the auto start 
function. To turn on the controller, a +15 signal (ignition) is required. With that, 
the standby light will be on, allowing the visualization of the temperatures if the 
panel is on.

Note 1:

 If the standby light is off and the Power button is pressed, the standby 

light will come on and the panel can be turned on. However, if no 
communication is established, the product will return to sleep mode.

Note 2:

 emergency mode: if the control panel does not establish communication 

with the panel, after 1 minute the control panel starts to operate automatically.

Note 3:

 when turning on the panel, the Firmware versions of the ECU SU021 and 

the Panel SC2000 are informed respectively by the abbreviations SUV xx and 
SCV xx.

1- Status indication of the actuators;
2- Set-point temperature;
3- Outside Temperature;
4- Return Temperature.

When starting the panel, automatic mode is activated (the corresponding key is 
illuminated in amber color).
The auto mode activated indicates that the evaporator fan speed and the air 
recirculation function are operating in automatic mode, as well as the compres-
sor drive. Automatic mode is disabled when any of the following occurs:

 • AC key pressed disabling the compressor;
 • Changing the fan speed using the key.

Evaporator ventilation is controlled by the Set-point together with the suction 
and discharge pressure values. To maintain the appropriate pressure value for 
the operation and reach the defined Set-point.

1.4.2- Automatic Compressor

The compressor is activated according to the difference between the Set-point 
and the return temperature, values defined by the parameters (P68 and P69).

CC 336 W - CC 356 W

11

Содержание CC 336 W

Страница 1: ...Rev 01 November 2023 Code 036 00353 001 Owner s Manual Warranty Certi cate CC 336 W CC 356 W AIR CONDITIONER COACHBUS CITY BUS...

Страница 2: ...______________________________________ 8 1 1 SC2000 Controller Operation_____________________________________________________ 10 1 2 Description of the Control Panel___________________________________...

Страница 3: ...tive and corrective maintenance procedures they must be accomplished by experts or dully technicians Looking for improving and updating the refrigeration technical teams this manual describes the fund...

Страница 4: ...d if the vehicle is still in use after the defect is found even if there is lack of pieces delay in transportation or any other such incident c If the warranty certificate and or the serial number of...

Страница 5: ...rent from alternator 1 Accomplish the trimestral check list 2 Clean the evaporator capillary tube coil Apply only water and neutral non aggressive soup to cooper and aluminum See note 3 Clean the evap...

Страница 6: ...s back again after 48 working hours It is recommended not use different brands Install assemblies with the same diameter length of the series and do not apply new belts beside old ones Putting the ass...

Страница 7: ...hiness at the belts and pulleys Gas Charge Process Leakage test procedure Vacuum process and refrigerant gas charge Note in case the installation is bad VALEO Agent Authorized Service Net will have to...

Страница 8: ...OPERATING THE AIR CONDITIONER 1 Operating the Air Conditioner Note illustrative drawing 17 14 2 8 1 16 7 15 6 13 11 13 5 4 3 12 18 9 9 10 19 19 16 11 CC 336 W CC 356 W 8...

Страница 9: ...ECTRIC SYSTEM Evaporators Now at evaporators the refrigerant fluid at low pressure turns from liquid to gaseous state absorbing the interior heat of the vehicle in this process Controller It is instal...

Страница 10: ...00 VAC SD Below is a description of each of the keys with their respective functions 1 ON OFF Turns the product ON OFF 2 AC Indicates that the compressor is ready for operation 3 Increment of the set...

Страница 11: ...e Panel SC2000 are informed respectively by the abbreviations SUV xx and SCV xx 1 Status indication of the actuators 2 Set point temperature 3 Outside Temperature 4 Return Temperature When starting th...

Страница 12: ...is enabled and turns on if necessary and if the minimum operating times are maintained The cooling function will be enabled Note the air conditioning compressor must be turned off for at least 1 minu...

Страница 13: ...uct Sensor Sensor aberto F15 Loop Sensor Sensor open or short circuited F17 Ice Sensor Sensor open or short circuited F19 UV Disinfection System Damaged lamps or ballasts 1 7 Failures When an error oc...

Страница 14: ...8 700 m3 h 11 600 m3 h Nominal Current 90A 124A Model Alternative Type TM65 Heavy Oscillating Plate TM65 Heavy Oscillating Plate Displacement 635 CM3 635 CM3 Maximum Rotation Allowed 4 000 RPM 4 000 R...

Страница 15: ...1 4 SEE NOTE Extruded Aluminum C Profile 1 5 SEE NOTE MPHE Condenser Coil 1 6 SEE NOTE Axial 24V 12 Electronic Condenser Fan 4 7 SEE NOTE Discharge Pipe Set 1 8 SEE NOTE Front Finish Cover 1 9 SEE NO...

Страница 16: ...id Valve 1 7 SEE NOTE TGEN 3 5 TR Expansion Valve 2 8 SEE NOTE RH Evaporator Coil 1 9 SEE NOTE LH Evaporator Coil 1 10 SEE NOTE RH Heating Coil 1 11 SEE NOTE LH Heating Coi 1 12 SEE NOTE Evaporator Li...

Страница 17: ...tps www valeo thermalbus com br_pt PRODUTOS PECAS DE REPOSICAO ITEM CODE DESCRIPTION QTY 1 SEE NOTE TM 65 Compressor 1 SEE NOTE 2A 2B Pulley 1 SEE NOTE 8PK Pulley 1 3 SEE NOTE Clutch Set without Pulle...

Страница 18: ...EE NOTE 2CP45 4 Temperature Sensor 1 3 SEE NOTE 24V Water Pump 1 4 SEE NOTE High Pressure Switch 1 5 SEE NOTE Low Pressure Switch 1 6 SEE NOTE External Temperature Sensor 1 7 SEE NOTE EPCOS 3K Tempera...

Страница 19: ...belts are not visible under certain conditions Special care must be taken when putting your hands near them 6 Welding Welding must be done carefully it causes burns and spray toxic gases out Provide v...

Страница 20: ...e preservation and pollutinon reduction of the environment creating economic growth through the Reverse Logistics Program According to Law 12 305 2010 the environmentally adequate destination of compo...

Страница 21: ...Valeo Climatiza o do Brasil Ve culos Comerciais S A Av Rio Branco 4688 Bairro S o Crist v o CEP 95060 145 Caxias do Sul RS Brasil Tel 55 54 2101 5700 www valeo thermalbus com br...

Отзывы: