3- Electric Control Board RODOVIARIO GL-T047 / 24V
Plant code:
007-00017-000
RENOVACIÓN
CONTROLLER
RENEWALL
1- PERNO 6 (MOTOR)
2- PERNO 4 (MOTOR)
OBSERVATION:
as you are handling
with commutation high current electric
device, it is necessary to install it in a
ventilated point, not closed built, far
from fuel, inflammable lines, risky
spot, fire and explosion material. The
device is not waterproof. Water spray
and drops can damage it.
4 - CLUTCH
6 - D +
1 - COND. 1
2 - COND. 2
3 - COND. 3
7 - COND. 6
8 - COND. 5
9 - COND. 4
5 - RENEWALL CONNECTION
1 - LOW EVAP. 1
2 - LOW EVAP. 2
3 - LOW EVAP. 3
1 - HIGH EVAP. 1
1 - N.C.
2 - HIGH EVAP. 2
2 - GROUND
FUSES:
RELAYS:
F3 - CLUTCH - 5A
F4 - LOW EVAP. 1 - 10A
F1 - CONDENSER 1 - 20A
F1 - CONDENSER 1 - 20A
F5 - LOW EVAP. 2 - 10A
F6 - HIGH EVAP. 4 - 15A
F7 - HIGH EVAP. 2 - 15A
F8 - HIGH EVAP. 3 - 15A
F9 - HIGH EVAP. 1 - 15A
F10 - CONDENSER 3 - 20A
F11 - CONDENSER 5 - 20A
F17 - CONDENSER 4 - 20A
F18 - CONDENSER 6 - 20A
F12 - LOW EVAP. 4 - 10A
F13 - LOW EVAP. 3 - 10A
F14 - LOW EVAP. 5 - 10A
F16 - LOW EVAP. 6 - 10A
F15 - HIGH EVAP. 5 - 15A
F19 - HIGH EVAP. 6 - 15A
RL2 - CLUTCH
RL1 - CONDENSER 1 AND 2
RL6 - CONDENSER 3 AND 4
RL7 - CONDENSER 5 AND 6
RL3 - LOW EVAP. 1 AND 2
RL8 - LOW EVAP. 3 AND 4
RL9 - LOW EVAP. 5 AND 6
RL10- HIGH EVAP. 5 AND 6
RL4 - HIGH EVAP. 3 AND 4
RL5 - HIGH EVAP. 1 AND 2
3 - HIGH EVAP. 3
3 - HIGH EVAP. CONNECTION
9 - LOW EVAP. 4
8 - LOW EVAP. 5
7 - LOW EVAP. 6
9 - HIGH EVAP. 4
9 - N.C.
8 - HIGH EVAP. 5
8 - N.C.
7 - HIGH EVAP. 6
7 - +24V DIR. BATTERY
6 - N.C.
6 - N.C.
6 - CONDENSER CONNECTION
5 - N.C.
5 - AIR CURTAIN
5 - +24V AP. IGNITION
4 - N.C.
4 - N.C.
4 - LOW EVAP. CONNECTION
Male terminal
for cables 0,5-2,5mm
2
ref. AMP: 880685-2
Connector
9 Way female
ref. AMP:880125-0
3
6
2 1 5
4
7
8
9
6,3
2
1
Connector
2 Way male TE
ref. AMP:
180907-0
6,3
Female terminal
for cables 0,5-2,5mm
2
ref. AMP:
735432-2
CC 305 - CC 335 - CC 355
ELECTRICAL SYSTEM
45
Содержание CC 305
Страница 2: ...ESPAÑOL ...