ELECTRICAL CONNECTIONS
A junction box can be found in the user manual
and must be installed on the lower right side
of the fireplace. Wiring must be fed to the
junction box and attached to the receptacle
that is provided. Leave approximately 6in of
wire in the junction box for connection.
CAUTION
All wiring should be done by a
qualified electrician and shall be
in compliance with all local, city
and state building codes. Before
making the electrical connection,
make sure that the main power
supply is disconnected. The fire-
place, when installed, must be
electrically grounded in accor-
dance with local codes, or in the
absence of local codes, with the
National Electrical Code ANSI/
NFPA 70 (Latest Edition).
Attach black wire to one side of the receptacle
and white wire to opposite side of receptacle.
The ground wire should be attached to the
green (ground) screw. See
.
BLACK (HOT)
BRASS SCREWS
JUNCTION BOX
GROUND
SILVER SCREWS
GREEN SCREW
WHITE
(NEUTRAL)
120 VOLT POWER SUPPLY
Figure 30
Install the receptacle into the junction
box. Attach cover plate. After the wiring is
completed to the junction box and receptacle,
install the junction box to the lower right side
of the fireplace as shown in
. Insert
the top flange of the retainer bracket into the
slot on the fireplace. Rotate the junction box
assembly downward, and secure with a screw
below the junction box. See
.
Control Module Access
To access the control module for servicing,
remove the barrier screen and glass door
assemblies. The control module is located in
the bottom right side opening.
Remove (1) #10 x 1/2 hex head. Screws that
secures the control cover, then shift the cover
to the left and upward to remove. The control
module is located to the fireplace bottom with
Velcro ®, and can be lifted up to access the
module wiring connections.
Figure 31
Once the Junction box has been installed with
the receptacle outlets facing inward towards
the fireplace, locate the 3-prong power cord
from the control module and plug into the
receptacle.
The fireplace is supplied with a User Interface
wall box that must be installed in a standard
plastic outlet box (not provided). A low voltage
orange or blue box is recommended. The
user interface wall box must be placed in the
wall within ten feet from the right side of the
fireplace. A 10ft. battery and user interface
extension wire harness is supplied.