Page 36
Installation and Operation Manual - FP12 Mundo II
ENGLISH
8.5.3 Framing with Fresh Air Intake
15
B
C
A
B
If a finishing material is installed inside the enclosure, its thickness must be added to the following
measurements.
A
: Fresh air intake duct
16
(Fresh air intake can be installed on the right or underneath).
B
: Distance between framing and side fireplace standoff 12" (305 mm)
C
: Framing width (Installation with centered fireplace) 75
¼
" (1911 mm)
8.5.4 Framing with forced air distribution kit17
E
E
F
D
D
If a finishing material is installed inside the enclosure, its thickness must be added to the following
measurements.
D
: Forced air duct
18
(Duct can be installed on the left [recommended]
or
on the right).
E
: Distance between framing and side fireplace standoff 18" (457 mm)
F
: Framing width (Installation with centered fireplace) 87
¾
" (2216 mm)
15
Framing dimensions are for reference only. These measurements are recommended to prevent the ducts from being inside the standoff or have
too tight duct curves. Smaller dimensions can be used depending on the size and type of duct as well as the configuration of the installation.
16
HVAC duct, as per ULC S110 or UL 181, class 0 or class 1, must withstand temperatures up to 250oF.
17
Framing dimensions are for reference only. These measurements are recommended to prevent the ducts from being inside the standoff or have
too tight duct curves. Smaller dimensions can be used depending on the size and type of duct as well as the configuration of the installation.
18
HVAC duct, as per ULC S110 or UL 181, class 0 or class 1, must withstand temperatures up to 250oF.