Page 30
Owner’s Manual - L48
ENGLISH
7. Inlet and outlet gas test ports.
INLET TEST PORT
OUTLET TEST PORT
G
DETAIL G
H
DETAIL H
5/16"
8. Replace the gas valve by removing the two 5/16 in
hex-head screws on top of the gas control bracket.
The gas valve and bracket can be lifted up to gain
access to the flex line connections.
F
DETAIL F
E
DETAIL E
12 X
5/16"
5/16"
5/16"
2X
7.4.1 Accessing the Control Module
Always turn off gas and electrical supply to the fireplace before servicing the controls.
1. Remove the barrier screen and glass door assemblies, and set them aside in a safe location.
2. It is not necessary to remove decorative glass media from the burner cover or accent glass panels
to gain access to the control module.
3. The control module is in the lower
front corner of the fireplace bottom. It
is secured to the fireplace with Velcro.
The gas control and variable halogen
lighting wiring is routed through the
lower right side opening to the gas
valve and variable halogen lighting wire
connections in the firebox. The 120V
power cord is routed through the lower
right side opening and plugged into the
Junction Box receptacle.
G
DETAIL G
H
DETAIL H
5/16"
Содержание FG00001