background image

 

32

VALCOURT LIMITED LIFETIME WARRANTY 

 

The warranty of the manufacturer extends only to the original consumer purchaser and is not transferable. This warranty covers brand 
new products only, which have not been altered, modified nor repaired since shipment from factory. Products covered under this 
warranty must have been manufactured after the revision date indicated below. Proof of purchase (dated bill of sale), model name and 
serial number must be supplied when making any warranty claim to your VALCOURT dealer.   

This warranty applies to normal residential use only. Damages caused by misuse, abuse, improper installation, lack of 
maintenance, over firing, negligence or accident during transportation, power failures, downdrafts, or venting problems are not 
covered by this warranty. 

This warranty does not cover any scratch, corrosion, distortion, or discoloration. Any defect or damage caused by the use of 
unauthorized parts or others than original parts void this warranty. An authorized qualified technician must perform the installation in 
accordance with the instructions supplied with this product and all local and national building codes. Any service call related to an 
improper installation is not covered by this warranty. 

The manufacturer may require that defective products be returned or that digital pictures be provided to support the claim. Returned 
products are to be shipped prepaid to the manufacturer for investigation. If a product is found to be defective, the manufacturer will 
repair or replace such defect. Transportation fees to ship the product back to the purchaser will be paid by the manufacturer. Repair work 
covered by the warranty, executed at the purchaser’s domicile by an authorized qualified technician requires the prior approval of the 
manufacturer. Labour cost and repair work to the account of the manufacturer are based on predetermined rate schedule and must not 
exceed the wholesale price of the replacement part. All parts and labour costs covered by this warranty are limited according to the table 
below.   

The manufacturer at its discretion may decide to repair or replace any part or unit after inspection and investigation of the defect. The 
manufacturer may, at its discretion, fully discharge all obligations with respect to this warranty by refunding the wholesale price of any 
warranted but defective parts. The manufacturer shall in no event be responsible for any special, indirect, consequential damages of any 
nature, which are in excess of the original purchase price of the product. A one-time replacement limit applies to all parts benefiting 
from a lifetime coverage. This warranty applies to products purchased after October 1

st

, 2011. 

 

DESCRIPTION

 

WARRANTY APPLICATION 

PARTS LABOUR 

Combustion chamber (welds only), castings, convector air-mate, ceramic glass (thermal 
breakage only*), and secondary air tubes*. 

Lifetime 

4 years 

Plating* (defective manufacture) – subject to limitations above. 

Lifetime 

n/a 

Stainless steel firebox components, surrounds and heat shields, ash drawer, steel legs, pedestal, 
trims (aluminum extrusions),  C-Cast baffle*, and vermiculite baffle*. 

5 years 

3 years 

Carbon steel firebox components, glass retainers, and handle assembly. 

3 years 

2 years 

Blowers, heat sensors, switches, rheostat, wiring, and other controls. 

2 years 

1 year 

Paint (peeling), gaskets, insulation, firebrick, and ceramic fibre blankets. 

1 year 

n/a 

*Pictures required 

 

Shall your unit or a components be defective, contact immediately your 

VALCOURT 

dealer. Prior to your call make sure you have the 

following information necessary to your warranty claim treatment: 

 

 

Your name, address and telephone number;  

 

Bill of sale and dealer’s name; 

 

Serial number and model name as indicated on the 
nameplate fixed to the back of your unit; 

 

Nature of the defect and any relevant information. 

 
Before shipping your unit or defective component to our plant, you must obtain from your VALCOURT dealer an 
Authorization Number. Any merchandise shipped to our plant without authorization will be refused automatically and 
returned to sender. 

 

Содержание Beaumont

Страница 1: ...Copenhague Saint Augustin de Desmaures Quebec G3A 2H3 Tel 418 878 3040 Fax 418 878 3001 valcourtinc com This manual is available for free download on the manufacturer s web site It is a copyrighted d...

Страница 2: ...OTING 26 HEAT DISTRIBUTION SYSTEMS 27 GRAVITY DISTRIBUTION KIT 27 FORCED AIR DISTRIBUTION KIT 28 HEAT DISTRIBUTION SYSTEMS 30 VALCOURT LIMITED LIFETIME WARRANTY 32 REGISTER YOU WARRANTY ONLINE To rece...

Страница 3: ...ulatory requirements We recommend that our wood burning hearth products be installed and serviced by professionals who are certified in the United States by NFI National Fireplace Institute or in Cana...

Страница 4: ...onnected to the fireplace CHIMNEY MANUFACTURER BRAND TYPE INNER DIAMETER Selkirk Ultra Temp UT 1 Solid Pack 7 178 mm Selkirk Super Pro SPR 1 Solid Pack 7 178 mm Selkirk Super Vent JSC 1 Solid Pack 7 1...

Страница 5: ...here temperatures are consistently below freezing 32 F 0 C installing the chimney outdoors promotes functional problems such as insufficient draw excessive creosoting and difficult fire ignition In ad...

Страница 6: ...6 Figure 2 Various Fireplace Locations Figure 3 Possible Chimney Configurations Figure 4 Fireplace Framing...

Страница 7: ...s such as wood or plywood or any other hard sturdy surface 4 A 48 x 16 1220 mm x 407 mm minimum hearth extension made of non combustible material is required The extension can be installed below the b...

Страница 8: ...the inside insert the insulated flexible duct and attach it to the inlet grill with aluminum duct tape or 19 mm metal screws 13 On the lower left side of the fireplace remove the metal piece blocking...

Страница 9: ...ed fireplaces and ANSI Z233 1 with regards to the National Gas Code ATTENTION ALWAYS OPEN THE CHIMNEY DAMPER TO ITS MAXIMUM POSITION WHEN USING A DECORATIVE GAS APPLIANCE THIS FIREPLACE HAS NOT BEEN T...

Страница 10: ...is 9 ft 2 75 m for 2 Solid Pack Chimney and 12 ft 3 7 m for 1 Solid Pack Chimney 6 The chimney must extend at least 3 ft 92 cm above its point of contact with the roof and at least 2 ft 61 cm higher...

Страница 11: ...11 Figure 7a Figure 7b...

Страница 12: ...the chase enclosure and at least 2 ft 61 cm higher than any wall roof or building within 10 ft 3 1 m of it See Figure 7c and 7d to determine the configuration that applies to your roof flat or sloped...

Страница 13: ...be a minimum of 1 between the outside of the masonry and any wood framing or loose insulation 3 The chimney must be built in accordance with the current building code 4 No other appliance can be conn...

Страница 14: ...you reach the hole level 5 Slip through the hole a 45 or 30 liner elbow and connect it to the liner 6 Add a small liner section to the liner elbow which will allow the liner to extend at least 12 mea...

Страница 15: ...igh enough you can install one or more EXCEL chimney lengths directly on the fireplace before the elbow To make the hole through the masonry chimney and make the connection to the fireplace we recomme...

Страница 16: ...16 Figure 8 Excel Chimney Installation Figure 9 Security Chimney Installation...

Страница 17: ...17 Figure 10 Straight Chimney Installation Figure 11 Chimney Installation with Elbows Figure 12 Chimney Installation through an Exterior Wall Figure 13 Isolated Chase Chimney Installation...

Страница 18: ...imney enclosure Figure 15 6 It is possible to enclose the top and sides of the appliance but a minimum clearance of 2 51 mm must be provided around the chimney Figures 15 6 1 In the U S it is not perm...

Страница 19: ...19 Figure 15 Chimney Enclosure...

Страница 20: ...20 Figure 16a Mantel Positioning...

Страница 21: ...21 Figure 16b Combustible material positioning A 48 in B Radius of 84 in C 84 in Min...

Страница 22: ...22 Figure 17 Installation of Fireplace Facing...

Страница 23: ...rn 11 During the first fires you may detect a certain odor and the coating and oil protecting certain appliance parts may smoke a little If you open a window these will quickly dispel 12 It could also...

Страница 24: ...place have it inspected by the Fire Department MAINTENANCE 1 Clean color trim with soapy water and a soft cloth Do not use any metal polish or abrasives 2 Keep the glass relatively clean Dirty windows...

Страница 25: ...IN AN BEAUMONT FIREPLACE Do not use the fireplace with a broken or missing firestone 1 Remove the front refractory brick FP2 071 5 2 Remove the upper deflector FP2 004A holding the side wall stones in...

Страница 26: ...rease air supply 5 Any type of fan range hood or bathroom exhaust fan that draws air outside can create negative pressure Shut off the fan and or open a window near the fireplace to solve this problem...

Страница 27: ...TRIBUTION KIT The Gravity Distribution Kit FP4 300 may be used to heat rooms located above behind and either side of the room where the fireplace is located Note that if the hot air outlets are locate...

Страница 28: ...at adjacent rooms or lower floor located up to 50 15 2 m from your Valcourt Fireplace Only 6 15cm flexible isolated duct can be use for this installation Figure 20 If the fan is install with a rheosta...

Страница 29: ...th local regulations as well as the applicable National Building Code standards Install the rheostat close to the fireplace so it can be easily closed whenever you must open the fireplace doors If the...

Страница 30: ...30 HEAT DISTRIBUTION SYSTEMS...

Страница 31: ...31...

Страница 32: ...lesale price of the replacement part All parts and labour costs covered by this warranty are limited according to the table below The manufacturer at its discretion may decide to repair or replace any...

Отзывы: