background image

 

 

 

 
 

 

 

Issue 1 

 

947538 

 

 

VIP-9895-IC 

InformaCast

®

 Compliant 

IP EMERGENCY WALL MOUNT CALL STATION 

 
 

INTRODUCTION

 

The VIP-9895-IC IP Emergency Wall Mount Call 
Station provides emergency communication to 
any SIP telephone, InformaCast intercom or to a 
Valcom IP Gateway.  At the time of activation, 
the high intensity blue LED changes from 
beacon mode to flash mode.  The LED will 
continue to flash until the call is terminated.   
 

SPECIFICATIONS 

 

Features 

 

Power over Ethernet (PoE) (802.3af) 

 

Call button calls a SIP address InformaCast 
intercom or any Valcom Gateway 

 

Combination LED Beacon/Flasher 

 

Network programmable for control and setup 

 

Vandal and Tamper resistant 

 

Stainless steel enclosure, brushed stainless 
steel grille and hardware 

 

Available in several standard color 
combinations 

 

Environment

 

 

Suitable for Indoor/Outdoor installations

 

 

Networking

 

 

10/100 Mbps Ethernet port 

 

Manual or Dynamic Host Configuration 
Protocol (DHCP) IP address setup 

 

Dimensions/Weights

 

 

32.15” H x 9.9” W x 8.0” D 

       (81.66 cm x 25.1 cm x 20.3 cm) 

 

Shipping weight: 39.75 lbs. (18.1kg) 

Mounting

 

 

Surface mount 

 

Power

 

 

PoE: 802.3af, class 3 

 

Speaker Output

 

 

100dB@4’ on-axis

 

 

High efficiency design for

 

       voice intelligibility

 

 
 
 

INSTALLATION

 

When removing or reinstalling security 
screws, start screws by hand before 
tightening with a hand or power driver tool.  
If using a power driver, operate it at very low 
speed to help prevent thread seizing. 

 

 

Using security hex driver carefully remove 
top and set aside with hardware. 

 

Using the security hex driver, carefully 
remove the front speaker panel.  While 
supporting the panel, unplug connector from 
main circuit board at the top of the speaker 
(“A” in photo).  Loosen screws from relay 
connector on the small circuit board 
attached to the speaker housing, and 
disconnect the two white wires from the relay 
(“B” in photo).  Set speaker panel and 
hardware aside. 

 

Install base using appropriate hardware, with  
supplied (4) 1.5” neoprene washers between 
base and mounting surface. 

 

Connect earth ground to base (ground may 
be connected using one of the mounting 
screws). 

 

Connect RJ45 from network to Ethernet jack 
on main circuit board (“C” in photo).   Power 
over Ethernet (PoE) is required.  If PoE is 
not available from the switch, an inline power 
injector will be required. 