Mounting

 

For enhanced protection against static 
electrical discharge, it is recommended        
the VIP-9890A-EM-IC Speaker Enclosure            
be installed onto a grounded electrical box, If 
surface mounted, ground box to local ground.  
 

The VIP-9890A-EM-IC speaker enclosure is 
designed for double gang FD electrical box 
mounting and must be within 100 meters of the 
network switch.   
 
Remove the speaker assembly from the packing 
container.  Using a Phillips screwdriver, remove 
the screws securing the front grille to the 
enclosure.  Unplug the patch cable connecting 
the speaker to the network board Signal Output 
RJ-45 jack to allow removal of grille/speaker 
assembly.  Pre-drilled 13/64” mounting holes in 
the back of the enclosure are designed to fit a 
single gang, double gang or octagon outlet box.  
If not attaching to an outlet box, use the 
enclosure as a template.  Hold the enclosure in 
the desired position on the wall and mark the 
location of mounting holes.  Depending on wall 
construction type, prepare the mounting hole 
locations on the wall to securely attach the 
enclosure. 
 
Wiring may be inserted through the large hole in 
the back of the enclosure, or through the 
knockout hole in the top of the enclosure.  Insert 
wiring for network connections and relay 
connections (if used) through desired hole.  Use 
mounting hardware (not included) appropriate for 
the wall type to securely mount the enclosure to 
the wall. 
 
After making all connections, align the 
grille/speaker assembly with the enclosure.  
Install the four supplied tamper-resistant screws 
through the grille into the enclosure.  Use a 1/8” 
security hex bit to tighten the screws securely. 

 
Power Connections 

The only method of powering a VIP-9890A-EM-IC 
is via a Power over Ethernet (PoE) switch or 
power injector meeting the 802.3af specification. 
  
Make all required connections before connecting 
to Ethernet switch or power injector meeting the 
802.3af specification.

Network Board Connections 

The VIP-9890A-EM-IC network board has one  
RJ-45 NETWORK connector and one RJ-45 
Signal Output connector.  Use a standard 
Ethernet patch cable to connect the NETWORK 
connector of the VIP-9890A-EM-IC network 
board to an Ethernet switch.  A patch cable is 
provided that connects the Signal Output 
connector to the speaker board RJ-45 connector. 

 

Door Relay Connections 

Access to the form C relay is provided via a 
three-pin screw terminal block on the VIP-9890A-
EM-IC speaker.  The common contact is the 
middle terminal.  The Normally Open contact is 
on the side labeled NO, the Normally Closed 
contact is labeled NC. 
 
 

Status Indicator Lights 

The VIP-9890A-EM-IC network board has 2 
status indication lights on the Ethernet connector:

 

 

Green LED:

 (Link) Indicates Ethernet 

connection when illuminated. 
 

Yellow LED:

 (Activity) Indicator flashes to 

indicate network activity. 
 

Setup 

The VIP-9890A-EM-IC will automatically acquire 
an IP address (using DHCP) and connect to the 
InformaCast server when connected to the 
network and powered up.  Information specific 
to your application will need to be programmed 
into the InformaCast server.  Refer to the 
InformaCast documentation for further 
Information. 
Programming for optional features, such as Relay 
activation, can be entered using the VIP-102B IP 
Solutions setup tool.  The VIP-102B 
Programming tool may be downloaded from the 
Valcom website at 
www.valcom.com/vipsetuptool.