                                                              3                                                               947704 

 

Network Connection 

The VIP-9890-CB Network Interface has one  
RJ-45 NETWORK connector and one RJ-45 
DOOR connector. 

 

Use a standard Ethernet patch cable to connect 
the NETWORK connector of the VIP-9890-CB 
Network Interface to an Ethernet switch.  
 

Signal Connections 

Use standard Category 5 UTP cable to connect 
the VIP-9890-CB Network Interface to the 
Intercom unit.  Connect the RJ-45 jack (labeled 
Door) on the Network Interface to the RJ-45 jack 
on the back of the Intercom unit speaker 
assembly using a standard Ethernet patch cable. 

 

Door Relay Connections 

Access to the form C relay is provided via a three 
pin screw terminal block on the VIP-9890-CB 
Intercom unit.  The common contact is the middle 
terminal.  The Normally Open contact is on the 
side closest to the RJ-45 connector, the Normally 
Closed contact is on the side furthest from the 
RJ-45 connector.  Please refer to Figure 1. 
 
For higher security, the included VIP172L-RLY 
connection block can be used.  Please refer the 
Quick Start Installation guide packaged with the 
VIP172-RLY for installation details. 
 

Aux Input 

Aux input on the VIP-9890-CB Network Interface 
accepts line level audio such as background 
music and broadcasts it through the Intercom unit 
speaker. When the call button is pressed, the aux 
input is muted and remains muted until the call is 
terminated. 

 

Status Indicator Lights 

The VIP-9890-CB Intercom unit is equipped with 
a status indicator

 

LED. LED flashes when the call 

button is pressed and steady when the call is 
connected. 
 
The VIP-9890-CB Network Interface has 3 status 
indication lights on the side panel: 

 

STATUS: 

Flashes during normal operation, and 

solid during system startup.. 

 

LINK:

 Indicates 100 Mbit Ethernet connection 

when illuminated.  No activity indicates 10 Mbit 
connection. 

 

ACT:

 Indicator flashes to indicate network 

activity. 
 

Setup 

Information specific to your application will need 
to be programmed into the VIP-9890-CB using a 
computer.  The PC used for programming should 
be connected to the same subnet as the  
VIP-9890-CB. 
 
Setup will be done using the IP Solutions Setup 
Tool.  Download the latest version of the free IP 
Solutions Setup Tool from the Valcom web site at 
www.valcom.com/vipsetuptool. 
 

TECHNICAL ASSISTANCE 

Assistance in troubleshooting is available from 
the factory. Call (540) 563-2000 and press 1 for 
Technical Support or via email at 
[email protected]

When requesting assistance, you should include 
all available information.  Information and trouble-
shooting procedures are available on the Valcom 
website at www.valcom.com. 

Valcom equipment is not field repairable.  
Valcom, Inc. maintains service facilities in 
Roanoke, VA.  Should repairs be necessary, 
attach a tag to the unit clearly stating your 
company name, address, phone number, contact 
person and the nature of the problem. Send the 
unit to:

 

Valcom, Inc. 

Repair & Return Dept. 

5614 Hollins Road 

Roanoke, Va. 24019-5056  

 
 

 

                  

 
 
 
 
 
 
 
 
 