Valcom VIP-581A-IC Скачать руководство пользователя страница 3

 

 

3                                                             947579 

 

 

Power Connections 

The only method of powering a VIP-581A-IC IP 
FlexHorn is via a Power over Ethernet (PoE) 
network switch or power injector meeting the 
802.3af specification. 

 

Network Connection 

The VIP-581A-IC has one Ethernet RJ-45 
network connector on the circuit board.  Connect 
an Ethernet patch cable from the network switch 
to the VIP-581A-IC Ethernet RJ-45 socket before 
attaching the grille to the enclosure. 
 

Signal Connections 

Signal connections from the network interface to 
the FlexHorn are provided through an attached 
wiring harness pre-wired at the factory.  If the 
horn was disconnected while mounting the 
enclosure, reconnect the two-wire harness to 
screw terminals labeled SPEAKER on the 
network interface board before attaching the grille 
to the enclosure. 

 
Status Indicator Lights 

The VIP-581A-IC Network Interface has 2 status 
indicator lights on the RJ-45 Ethernet connector.   
 

Green LED:  

(Link) Indicates Ethernet connection 

when illuminated. 

 
Yellow LED: 

(Activity) Indicator flashes to 

indicate network activity. 
 

Setup 

The VIP-581A-IC will automatically acquire an IP 
address (using DHCP) and connect to the 
InformaCast server when connected to the 
network and powered up.  Information specific 
to your application will need to be programmed 
into the InformaCast server.  Refer to the 
InformaCast documentation for further 
Information.

TECHNICAL ASSISTANCE 

Assistance in troubleshooting is available from 
the factory.  Call (540) 563-2000 and press 1 for 
Technical Support or via email at 
[email protected]. 

When requesting assistance, you should include 
all available information.  It is strongly suggested 
that you go to the web site and follow the trouble 
resolution procedure at http://www.valcom.com. 

Valcom equipment is not field repairable.  
Valcom, Inc. maintains service facilities in 
Roanoke, VA.  Should repairs be necessary, 
attach a tag to the unit clearly stating your 
company name, address, phone number, contact 
person and the nature of the problem. Send the 
unit to:

 

Valcom, Inc. 

Repair & Return Dept. 

5614 Hollins Road 

Roanoke, Va. 24019-5056 

 

WARRANTY 

Warranty information may be found on our 
website at www.vacom.com/warranty. 

  

 
 
 
 
 
 
 
 
 

 