background image

 

                                                                  3                                                                         947591 

SPEAK

ER

L

ED 1

L

ED 2

-10
d

B L

INE

L

EVEL

 O
UT

M

UTE

SWITCH 2

SWITCH 1

GROUND

NETW

O

RK

RES

ET

+

-

- +

RED

BLACK

 
 
 
 
 
 
 

 
 

Figure 3. Molex Connector 

 
Speaker Mounting 

Remove the screw holding the mounting bracket to 
the enclosure.  Mount the bracket using appropriate 
hardware such as #8 pan head crews.  After 
making the required connections, reattach the 
enclosure to the mounting bracket. (Figure 5). 
 

Speaker Connections

  

Connect the attached wire assembly from the        
speaker to the speaker screw connections on        
the clock circuit board. (Figure 4). 

 
Network Connection 

The VIP-4171-A12-IC has one RJ-45 network 
connector on the rear panel.  Use a standard 
Ethernet patch cable to connect the unit to an 
Ethernet switch.

 

 
 
 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

Figure 4. IP CLOCK/SPEAKER CONNECTIONS

Call Switch Connection 

For IP Speakers using Talkback functionality, a call 
switch input via screw terminals is provided.  
Connect a momentary contact switch to Switch 1 
and Ground. 
 

-10 dB Line Level Out Connection 

The -10dBm Line Level Out may be connected to 
up to 40 Valcom Self Amplified Speakers in order to 
provide additional sound reinforcement in an area

 

LED 1 and LED 2 Connection 

LED 1 (+) and LED 2 (-) is a current limited output 
designed to illuminate an optional LED.  The LED  
is intended to provide visual indication of call 
progress.  The LED illumination will flash when the 
call switch is pressed and will continue to flash until 
the call is answered.  The LED illumination will be 
solid when a connection to the unit is established. 

 

SETUP

 

The VIP-4171-A12-IC will automatically acquire an 
IP address (using DHCP) and connect to the 
InformaCast server when connected to the 
network and powered up. Information specific 
to your application will need to be programmed 
into the InformaCast server. Refer to the 
InformaCast documentation for further 
information.

Отзывы: