background image

 

 

 

 

 

Issue 1 

 

1

 

947591 

 

CAUTION:  To reduce the risk of electric shock,

 

Do not remove cover (or back).

 

 

No user serviceable parts inside.

 

Refer servicing to qualified service personnel.

 

CAUTION

 

RISK OF ELECTRIC SHOCK

 

DO NOT OPEN

 

This symbol indicates that dangerous

 

voltage constituting a risk of electric

 

shock is present within this unit.

 

This symbol indicates that there are

 

important operating and maintenance

 

instructions in the literature accompanying

 

this unit.

 

 Issue 1 

 

VIP-4171-A12-IC 

       InformaCast® Compliant 

IP ANALOG CLOCK / SPEAKER WALL MOUNT  

 
INTRODUCTION 

The VIP-4171-A12-IC InformaCast Compliant IP 
Clock with Speaker includes a 

12” Analog Clock 

and a Wall Mount Speaker.  The wall speaker is an 
8” interior talkback speaker.  This provides 
synchronized time, talkback intercom and 
loudspeaker paging from one IP network 
connection.  The 

12” Analog Clock will sync its time 

with the InformaCast Server.  The speaker 
enclosure is made of steel with a durable powder 
coated finish.  The color of the enclosure can be 
easily changed to match any décor.  A cloth 
covered detachable grille is included with the 
speaker.  Power is provided to both the clock and 
speaker via a Power over Ethernet (PoE) switch 
meeting the 802.3af specification. 
 

SPECIFICATIONS 

Features 

 

SIP Compatible 

 

Only one network connection required 

 

Power over Ethernet (PoE) 802.3af compatible  

 

High Efficiency Speaker 

 

DIMENSIONS/WEIGHT 

– 4 Digit 

 

Clock 

– 12.81” diameter x 1.20” depth  

Weight: 3.70 LBS 

 

Speaker - 

10.13” H x 12.31” W x 4.63” D 

       (25.73cm x 31.27cm W x 11.75cm D) 

Weight: 4.25 LBS (1.9 kg) 
 

Nominal Power Requirements 

Via 802.3af PoE Ethernet Switch:

               

Class 3 

PSE (Power Sourcing Equipment) to be compliant 
to IEEE 802.3af 

 

Environment 

 

Temperature: 

                                    0 to +40° C 

Humidity:     

             0 to 85% non-precipitating 

 
These  products  are  intended  for  use  with  a  UL 
Listed  power  source  marked  “Class  2”  or  “LPS” 
rated 24VDC, or 48VDC (PoE). 
PoE  and  all  interconnected  ITE  are  intended  for 
intra-building.   

 
                                     

 
  
 
 
 

 

 

 
 
Precautionary Designations 

 

WARNING

To Reduce The Risk Of Fire Or 

Electric Shock.  Do Not Expose This 
Apparatus To Rain Or Moisture.

 

 

AVERTISSEMENT: Afin de réduire les 
risques d'incendie ou de décharge 
électrique, évitez d'exposer le système à la 
pluie ou à l'humidité. 

 

Apparatus shall not be exposed to dripping 
or splashing and no objects  

  

filled with liquids, such as vases, shall be 
placed on the apparatus. 

 

L’appareil ne doit pas être exposé à des 
égouttements et éclaboussures et  
aucun Objet Rempli de liquide, comme 
vase, ne doit être placé sur l’appareil. 

 

 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 

Отзывы: