3                                                                                       947460 

+24V DC

1

PHONE PHONE

2

K1

K2

N.
C.

N.
O.

N.
C.

N.
O.

COM

COM

K3

COM

N.
O.

COM

N.
C.

N.
O.

N.
C.

K4

If power is supplied via the barrel connector, 
make sure all signal connections are secure.  
Attach the unit to the network via the front panel 
RJ-45 Ethernet connector.  Apply power by 
plugging the power supply in to the 
VE8012A/VE8012AR via the barrel connector on 
the rear of the VE8012A/VE8012AR. 

 

Network Connection 

The VE8012A/VE8012AR has one RJ-45 network 
connector on the front panel. 

 

Use a standard Ethernet patch cable to connect 
the VE8012A/VE8012AR to an Ethernet switch.  
If the Ethernet switch is 802.3af compliant, the        
VE8012A/VE8012AR will draw power from it. 
 

Signal Connections 

On the back panel, the VE8012A/VE8012AR has 
2 RJ-11 jacks for telephone connection and 2 
terminal blocks for relay connections.  

 

Telephone Connections: 

Connect standard 

analog telephones to the VE8012A/VE8012AR 
via the back panel RJ-11 jacks labeled Phone 1 
and Phone 2.  Tip and Ring appear on pins 3 and 
4 of these jacks. 

 

Relay Connections: 

Access to the 4 form C 

relays is provided via two six pin screw terminal 
blocks.  The relays are labeled K1, K2, K3 and 
K4.  Each relay is brought out on three terminals. 
The common contact (COM) is the middle 
terminal with the normally closed (N.C.) contact 
on the right and the normally open (N.O.) contact 
on the left.  Relay contacts are rated for 1A @ 
24VDC. 
 
 
 
 
 
 

Rear View 

Setup

 

Information specific to your application will need

 

to be programmed into the VE8012A/VE8012AR 
using a computer.  The PC used for programming 
should be connected to the same subnet as the         
VE8012A/VE8012AR.

 

Setup will be done using the IP Solutions Setup

 

Tool. Download the latest version of the free IP 
Solutions Setup Tool from Valcom web site at 
www.valcom.com/vipsetuptool. 
 

Status Indicator Lights 

The VE8012A/VE8012AR has 3 status indication 
lights on the front panel: 

 

STATUS: 

Illuminates at regular intervals during 

normal operation.  On steady indicates unit is in 
reset mode.   
 
The network jack provides two LED indicators: 

 
Green LED:

 (Link) Indicates Ethernet connection 

when illuminated. 

 
Yellow LED:

 (Activity) Indicator flashes to 

indicate network activity. 

 
 
 
 
 
 

 

Отзывы: