Valcom VE8001 Скачать руководство пользователя страница 3

 

947651                                                                                    

Status
Link
Act

K1

K2

INPUTS

+24VDC

AUDIO CC

AUDIO 

OUT

AUX

IN

N.C

.

N.O

.

N.C

.

N.O

.

CO
M

CO
M

Network Connection

 

The VE8001/VE8001R has one CAT-5 RJ-45 
network connector on the front panel. 

 

Use the supplied CAT-5 patch cable to connect  
the VE8001/VE8001R to an Ethernet switch.   
If the Ethernet switch is 802.3af compliant the 
VE8001/VE8001R will draw power from it. 
 
 
 
 
 
 

 Front View

 

 
 
 
 

 
 
 
 

Rear View 

 

 
Signal Connections 

The VE8001/VE8001R has 4 I/O connectors on the 
rear panel: 

 

 

RCA jack for AUX audio input 

 

2 Pin screw terminal for audio output 

 

6 Pin screw terminal for relay connections 

 

4 Pin screw terminal for audio input and contact 

      closure input 

 

AUX Input: 

Local audio input is via the rear panel 

RCA jack.  Nominal input impedance is 600 Ohms. 
Connect any compatible audio source using an 
RCA patch cable. 

 

Audio Channels: 

Access to the networked audio is 

via screw terminals on the rear panel. 

 

The audio input and contact closure input share a 
four pin screw terminal connection.  Neither input is 
polarity sensitive.  The contact closure is on the 
right two terminals and is labeled “CC”.

Relay Channels: 

Access the two form C relays is 

provided via a six pin screw terminal block.  The 
relays are labeled K1 and K2.  Each relay is 
brought out on three terminals. The common 
contact is the middle terminal with the normally 
closed contact on the left and the normally open 
contact on the right.  Relay contacts are rated for 
1A @ 24VDC. 
 
Relays programmed for Supervise remain activated 
unless power is lost or a supervised VoIP device 
can be monitored. 

 

Status Indicator Lights 

The VE8001/VE8001R has 3 status indication lights 
on the front panel:  

 

STATUS: 

Flashes to indicate power. 

 

LINK:

 Indicates 100 Mbit Ethernet connection 

when illuminates. No activity indicates 10 Mbit 
connection. 

 

ACT:

 Indicator flashes to indicate network activity. 

 

SETUP 

Information specific to your application will need to 
be programmed into the VE8001/VE8001R using a 
computer.  The PC used for programming should 
be connected to the same subnet as the 
VE8001/VE8001R.  Setup will be done using the IP 
Solutions Setup Tool.  Download the latest version 
of the free IP Solutions Setup Tool from the Valcom 
web site at www.valcom.com/vipsetuptool.

Отзывы: