background image

 

 

 

 

 

Issue 1 

 

947551 

 

VE4122-A12 

IP CLOCK/SPEAKER ANALOG 2

’ x 2’ 

 

INTRODUCTION 

The VE4122-

A12 IP Clock with Speaker includes a 12” 

Analog Clock and a 2’ x 2’ Lay-in Ceiling Speaker.  
This provides synchronized time, talkback intercom and 
loudspeaker paging from one IP network connection.  
The Analog Clock can be programmed to sync with any 
NTP (Network Time Protocol) server.  Power is 
provided to both the clock and speaker via a Power 
over Ethernet (PoE) switch meeting the 802.3af 
specification. 
 

SPECIFICATIONS 

Features 

 

RJ45 network connection 

 

Shatterproof, polycarbonate crystal 

 

802.3af compatible  

 

High Efficiency 

 

DIMENSIONS/WEIGHT 

 

VE4122-A12 

– 12.81” diameter x 1.20” depth  

Weight: 3.70 lbs. (1.7 kg) 

 

V-CTLA 

–23.75” L x 23.75” W x 3.75” D 

(60.33 cm) x (60.33 cm) x(9.53 cm) 
Weight: 5.5 lbs.  (2.5 kg)

 

 

Nominal Power Requirements 

Via 802.3af PoE Ethernet Switch:

                       

Class 3 

 

Environment

 

Temperature: 

                                            0 to +45° C 

Humidity:     

                    0 to 85% non-precipitating 

 
These  products  are  intended  for  use  with  a  UL  Listed 
power source marked “Class 2” or “LPS” rated 24VDC, 
or 48VDC (PoE). 
PoE  and  all  interconnected  ITE  are  intended  for  intra-
building

 

Precautionary Designations 

• 

WARNING-To Reduce The Risk Of Fire Or 
Electric Shock.  Do Not Expose This Apparatus 
To Rain Or Moisture. 

•   AVERTISSEMENT - Afin

 de réduire les  

risques d'incendie ou de décharge 
électrique, évitez d'exposer le système à 
la pluie ou à l'humidité.

 

 
 
 
 
 
 
 
• 
  Apparatus shall not be exposed to 

dripping or splashing and no objects 
filled with liquids, such as vases, shall 
be placed on the apparatus. 

•  L’appareil ne doit pas être exposé à des 

égouttements et éclaboussures et 
aucun Objet Rempli de liquide, comme 
vase, ne doit être placé sur l’appareil. 

 

 

CAUTION:  To reduce the risk of electric shock,

 

Do not remove cover (or back).

 

No user serviceable parts inside.

 

Refer servicing to qualified service personnel.

 

CAUTION

 

RISK OF ELECTRIC SHOCK

 

DO NOT OPEN

 

This symbol indicates that dangerous

 

voltage constituting a risk of electric

 

shock is present within this unit.

 

This symbol indicates that there are

 

important operating and maintenance

 

instructions in the literature accompanying

 

this unit.

 

 

 

FCC Information 

This equipment has been tested and found to 
comply with the limits for a Class A digital device, 
pursuant to Part 15 of the FCC Rules.  These limits 
are designed to provide reasonable protection 
against harmful interference when the equipment is 
operated in a commercial environment.  This 
equipment generates, uses and can radiate radio 
frequency energy and if not installed and used in 
accordance with the instruction manual, may cause 
harmful interference to radio communications.  
Operation of this equipment in a residential area 
may cause harmful interference in which case the 
user will be required to correct the interference at 
one’s own expense.