Plastic Double Mount Installation

*For metal mounting bracket: Use a wall anchor that can support 50 lbs or more with a maximum 
screw size of 10/1.5”

Install metal mounting bracket - 

First, remove the metal mounting bracket from the inside of the double mount base by unscrewing 

the two (2) 6-32 x 1/2” screws located on the underside of the base (save these screws for step #5). Next, screw the metal mounting 

bracket to the wall or ceiling in which the clocks are being installed. To mount to the switch box, screw the four (4) 6-32 x 1” screws 

supplied in the assembly kit through the inner four holes of the metal mounting bracket. Use the outer four holes to mount anchors 

to the wall (both anchors and screws for anchors not supplied in kit). For IP clocks, if using an Ethernet bracket (*as shown in the 

diagram) use the two (2) 6-32 x 1/4” included in the assembly kit to mount the Ethernet bracket to the metal mounting bracket at this 

point(Ethernet bracket not supplied in assembly kit).

    

Note: if using a plastic switch box, a ground wire must be routed through the switch box and into one (1) of  

 

       the four (4) metal mounting bracket screws in order to provide ground to the metal mounting bracket.

   

Note: the metal mounting bracket 

MUST

 be secured by both the screws going to the switch box 

AND 

the  

 

 

anchors going into the wall.

Mount clock housings to pole - 

Align the hole in the center each housing with one of the three holes on the mounting pole where 

the wiring will be routed (the installer will chose which hole at the end of the pole to use based on how far they want the clock to sit 

from the wall). Screw from the inside of the housing into the four holes surrounding the hole in the center of the housing using the four 

(4) 8-32 x 7/16” screws supplied in the assembly kit (4 screws per clock), securing both housings to the mounting pole. 

 

 

Note: end caps from one side of each clock must be removed to mount both clocks to the mounting pole.  

 

 

Remove one end cap from each clock from the side in which the mounting pole enters the clock.

e

 

Screw both housings together - 

Using the two (2) self tapping, 6-19 x 7/16” screws supplied in the assembly kit, screw both back 

sides of the clock housings together (2 screws per clock).

r

  Feed wiring through base and pole - 

Take the wiring coming from the switch box and begin to feed it through the center of the 

base of the mounting assembly until it emerges from the hole in the center of the clock housing. Make sure there is roughly 1.5’ - 2’ 

of wiring coming from the switch box. Perform this task for both clocks. If installing IP clocks, run bare Ethernet wire without an RJ45 

connector and install the connector after it has been routed through the clock if possible (this will be much easier than running the wire 

with the connector on).  If not possible, make sure that there is no boot present in order for the connector to fit through the assembly. 

If you are using an Ethernet bracket with the installation of IP clocks, the assembly of the clocks in steps 6 and 7 can be accomplished 

before mounting the assembly to the wall in step 5 - making the overall installation more simple.

*instructions continued on next page 

Содержание V-D2425

Страница 1: ...V D2425 and V D2440 Digital Clock Installation Manual V1 03 Valcom Inc 5614 Hollins Road Roanoke VA 24019 540 563 2000 P 540 362 9800 F www valcom com...

Страница 2: ...ting 10 V D2425 and V D2440 Wired Clock Table of Contents 2 Flush Mount Installation 3 Surface Wall Mount Installation 4 Metal Double Mount Installation 5 Plastic Surface Wall Mount Installation 6 Pla...

Страница 3: ...Disconnect the red filter from the display panel 4 Connect the wiring as shown on the wiring diagram 5 IMPORTANT If using a low voltage system 24 volt make sure that the transformer is an isolated tra...

Страница 4: ...lcom com 4 Flush Mount Angled View Front View Side View H 4 65 W 10 3 Flush Mount Picture 2 5 Figure 1 Front view Flush Mount Angled View Front View Side View Flush Mount Picture 4 0 Figure 2 D3 28 D4...

Страница 5: ...nut included in the kit 3 Disconnect the red filter from the display panel 4 Connect the wiring as shown on the wiring diagram 5 IMPORTANT If using a low voltage system 24 volt make sure that the tra...

Страница 6: ...7 Insert the support bracket onto the hanger mounting rod 8 Screw the two 2 nuts included in the kit onto hanger mounting rod and secure the clock base to wall 9 Connect the ground wire into the doubl...

Страница 7: ...Valcom Inc 5614 Hollins Road Roanoke VA 24019 540 563 2000 P 540 362 9800 F www valcom com 7 Plastic Surface Wall Mount Installation e w q r t y Installation Instructions...

Страница 8: ...the inside of the housing and the four holes in the gang box Note If using a metal gang box a ground must be provided to the gang box w Feed Wiring Into the Housing Take the wire coming from the insi...

Страница 9: ...Valcom Inc 5614 Hollins Road Roanoke VA 24019 540 563 2000 P 540 362 9800 F www valcom com 9 Installation Instructions Plastic Double Mount Installation q t i a y r w w e u o...

Страница 10: ...les on the mounting pole where the wiring will be routed the installer will chose which hole at the end of the pole to use based on how far they want the clock to sit from the wall Screw from the insi...

Страница 11: ...e wiring harness and the switch box wires using wire nuts Perform this task for both clocks If using IP clocks wiring will not be supplied with the clocks the installer will be responsible for supplyi...

Страница 12: ...9 540 563 2000 P 540 362 9800 F www valcom com 12 Wiring Information Wiring and Jumper Settings Jumper Number On Off JP1 12 24 Hour Mode 12 Hour Mode 24 Hour Mode JP2 Brightness Brightest Bright JP3 L...

Страница 13: ...nication Wiring Information 18 19 110V EU 240V White Black White Black V D2425 or V D2440 V A2412 or V A2416 V CCU V C6124P 24 volt outputs 24 VDC IN DATA IN 19 18 2 W ire Digital Output to Clocks V C...

Страница 14: ...r wires NOTE If you fail to follow instructions a and b listed above the fuses can be blown Clock is only displaying dashes What do I do This means that the clock is receiving power but not receiving...

Страница 15: ...aster clock and resets itself to display the correct time This occurs within seconds of power up so no battery backup is required for a timekeeping base within the individual clocks Since the clock do...

Страница 16: ...nt and receiver 3 Connect the equipment into an outlet on a circuit different from that to which the receiver is connected 4 Consult the dealer or an experienced radio TV technician for help Complianc...

Отзывы: