The V-9943A is activated by 70-105 VAC (ring 
voltage) or -24 VDC (normally through an 
interrupted contact closure).   
An LED provides a visual indication when the unit 
is activated.  
 
The tones are dipswitch selectable.  The various 
tones available are described in the Option  Switch 
Chart along with the switch configuration 
necessary to obtain the tone. 
 
The dip switches and volume control are accessed 
through the opening in the rear of the enclosure

 
A. 

Setting the Dip Switches 

 
Switches 1-4 determine tone.  Switch 5 determines 
AC or DC operation. 
 

1. 

Determine if the equipment will be used  
with AC or DC current.  For DC current 
SW5 should be in the ON position.  For 
AC current (ring voltage) SW5 should be 
in the OFF position. 

 

CAUTION: Do Not Use Ring Voltage with SW5 
in the ON position. 

 
 

     2. 

Switches  1,  2,  3,  and  4  set  the  tones.    
Refer to the Option Switch Chart to obtain 
the setting of the desired tone. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

B.  

Setting the Volume Control 

The volume control is screwdriver adjustable.  
During initial setup, it is recommended the volume 
control be set 1/4 turn clockwise. 
 
C.   

Mounting 

The V-9943A has mounting holes located on the 
sides of the unit.  Two #10 x 3/4" wood screws are 
included for mounting purposes. 

 
 

TECHNICAL ASSISTANCE 

Assistance in troubleshooting is available from the 
factory.  When calling, you should have a Volt ohm 
meter and a telephone test set available and be 
calling from the job site.  Call (540) 563-2000 and 
Press 1 for Technical Support, or visit our website 
at http://www.valcom.com. 
 
Valcom equipment is not field repairable.  Valcom, 
Inc. maintains service facilities in Roanoke, VA.  
Should repairs be necessary, attach a tag to the 
unit clearly stating your company name, address, 
phone number, contact person, and the nature of 
the problem.  Send the unit to:

 

 Valcom, 

Inc. 

Repair and Return Dept. 

 

5614 Hollins Road 

 

Roanoke, VA  24019-5056 

 

Telephone System

Interrupted
Dry
Contact
Closure

T (1)

R (2)

V-9943A

Switch 5 
must be in
the ON
position

-24vdc

T (1)

R (2)

V-9943A

Switch 5 
must be in
the OFF
position

T

R

- OR -

90VAC Ring Voltage
from an assigned
station port on a
PABX, 1A2
Common audible
or a Central Office
Line

Input
Terminals

Volume
Control

Dip Switch

1

2

3

4

5