background image

 

 

 

 

2

 

 

applicable instructions for control equipment or any 
other equipment used. 
 

Precautions 

All precautions have been taken at the factory to 
insure that the equipment functions properly.  Please 
observe the following precautions or the equipment 
may be damaged and the warranty voided. 
a.    Unplug the power supply before connecting any 

wires or cables to the control units connecting 
block.  With power ON, accidental bridging of two 
terminals with a wiring tool may damage electronic 
circuits. 

b.    Do not use a lamp tester to check signals.  Use a 

voltmeter.  A lamp tester, when first applied is a 
short circuit to electronic circuits. 

c.    Do not apply power to the control unit until all 

connections have been double -checked. 

 
NOTE:  The V-9933A cannot be used to control 
music or on an audio zone with background 
music. 
 

Mounting 

a.    Select mounting location central to the noise 

producing equipment. 

b.    Carefully unpack the unit from the carton and 

inspect. 

c.    Unsnap cover from base and mount base to wall 

using pan head screws. 

 

Connections 

Refer to Figure 2 while performing the following: 
a.    Connect the page control unit speaker output to T 

and R input of V-9933A. 

b.    Connect the input of amplified speaker to T and R 

output of V-9933A. 

c.    Connect power supply -24VDC(-) and GND(+) to 

-24VDC and GND terminals on V-9933A. 

d.    Connect optional remote microphone (V-9934) to 

“Ext Mic In” terminals. 

 

Set-Up and Adjustment

 

a.    Complete all connections to page control unit,   V-

9933A, one-way amplified speakers and power 
supply.  Do not activate power supply until step c. 

b.    1)  Set the sensitivity adjustment fully clockwise 

for minimum ambient nois e environment. 
2)  Turn dip switch 1 ON (Setup) and set dip 
switches 2 and 3 to the desired range; typical 
range would be 2 OFF, 3 ON=30dB                (See 
Chart 1). 

 

3)  Set switch 4 to appropriate use. 

c.    Apply power to the V-9933A.  LEDs 8, 4, 2 and 1 

should briefly light in sequence and then go off.  If 
any LEDs remain lit, then a failure is indicated; 
repeating setup steps is recommended. 

d.    With the ambient noise at a minimum and no 

active program on the input, turn the sensitivity 
adjustment counter-clockwise until LED 1 
illuminates.  Make a test page and adjust the page 
volume controls to a suitable volume.  If 
necessary, the sensitivity adjustment may be 
increased.  However, it is not desirable for all 4 
LEDs to be lit during normal operation. 

e.    Return dip switch 1 to the OFF position. 
f.    Installation and set-up now complete. 
 

NOTE:  After adjusting “sensitivity adjust” 
(microphone gain), wait 20 seconds before 
executing a test page (See Troubleshooting 
Chart, Table 1).

 

 

TECHNICAL ASSISTANCE 

When trouble is reported, verify that power is being 
supplied to the unit and there are no broken 
connections.  Check voltages for proper polarity on 
terminals. 
 
Table 1 identifies symptoms of some possible problems 
with solutions.  If a spare unit is available, continue to 
troubleshoot by substituting the spare unit for the 
suspected defective unit. 
 
Assistance in troubleshooting is available from the 
factory.  When calling, you should have a VOM and a 
telephone test set available and be calling from the job 
site.  Call (540) 563-2000 and ask for Technical Support, 
or call (540) 767-1555 for Valcom 24-hour Faxback 
System or visit our website at http://www.valcom.com. 
 
The V-9933A is not field repairable.  

Valcom equipment 

contains no user serviceable parts inside.  

Valcom, 

Inc. maintains service facilities in Roanoke, VA.  
Should repairs be necessary, attach a tag to the unit 
clearly stating your company name, address, phone 
number, contact person and the nature of the problem.  
Send the unit to: 
 

Valcom, Inc. 

Repair and Return Dept. 

5614 Hollins Road 

Roanoke, VA 24019-5056

TABLE 1 - TROUBLESHOOTING CHART 

SYMPTOMS 

POSSIBLE SOLUTIONS 