manualshive.com logo in svg
background image

2

947932

INSTALLATION

These instructions cover only the installation
procedure of the Valcom V-9932.  Please consult
applicable instructions for control equipment or any
other equipment used.

Precautions

All precautions have been taken at the factory to
insure that the equipment functions properly.  Please
observe the following precautions or the equipment
may be damaged and the warranty voided.
a.  

 

Unplug the power supply before connecting any
wires or cables to the control unit connecting
block.  With power on, accidental bridging of
two terminals with a wiring tool may damage
electronic circuits.

b.  

 

Do not use a lamp tester to check signals.  Use a
voltmeter.  A lamp tester, when first applied is a
short circuit to electronic circuits.

c.  

 

Do not apply power to the control unit until all
connections have been double-checked.

NOTE:  The V-9932 cannot be used to control
music.

Mounting

a.  

 

Locate a space on the wall central to the noise
producing equipment.

b.  

 

Carefully unpack the unit from the carton and
inspect.

c.  

 

Unsnap cover from base and mount base to wall
using pan head screws.

Connections

Refer to Figure 2 while performing the following:
a.  

 

Connect the page control unit speaker output to T
and R input of V-9932.

b.  

 

Connect the input of amplified speaker to T and
R output of V-9932.

c.  

 

Connect power supply -24VDC and ground to
-24 and GND terminals on V-9932.

Set-Up and Adjustment

a.  

 

Complete all connections to page control unit,
V-9932, one-way amplified speakers, and power
supply (refer to applicable instructions).

b.  

 

With background noise at its lowest level, access
page system and adjust level controls on page
control and speakers for proper sound level.

c.  

 

Turn on all noise producing equipment for
maximum background noise level.

d.  

 

Access page and test.
NOTE:  The V-9932 microphone gain is factory
adjusted.  This adjustment is correct for most
applications.

e.  

 

If page volume with maximum background is too
high, turn microphone gain control counter
clockwise in small increments and test.
Important:  Wait at least 10 seconds after
adjusting microphone gain before accessing
page and testing.

f.  

 

If page volume with maximum background noise
is too low, turn microphone gain control
clockwise in small increments and test.
Important:  Wait at least 10 seconds after
adjusting microphone gain before accessing
page and testing.  Do not adjust microphone
gain beyond the point where the LED lights.

g.  

 

Installation and set-up now complete.

Valcom
  Page
Control
  Unit

T

R

V-9932

Power
Supply

-24V

GND

T

R

IN

OUT

     To
Telephone
  System

      Maximum 150 Amplified
One-Way Speaker Assemblies

Zone A

T

R

Figure 1 - Simplified Block Diagram of Connections