INTRODUCTION
The Zone Expansion Unit (ZEU) provides up to
16 zones of audio output (including talkback),
contact closure outputs or inputs.
SPECIFICATIONS
(see Table 2)
FEATURES
•
Provides same features as PagePac Plus
Controller
•
Maximum of 3 ZEUs per Controller
Power Requirements
•
Power from the PagePac Plus Controller
through the interconnect cable
Dimensions/Weight
•
16.00”W x 1.75”H x 6.88”D
(40.64cm x 4.45cm x 17.48cm)
•
3.0 lbs (1.36 kg)
Environment
•
Temperature 0 to +40° C (+32 to +104° F)
•
Humidity:
5 to 95% (non-condensing)
Locate in an area free of excess moisture,
corrosive gases, dust and chemicals.
INSTALLATION
MOUNTING
NOTE:
When installing the Zone Expansion
Unit, leave at least four inches of space above
and below for proper ventilation.
Installing the paging equipment in a ventilated
room where there is easy access to speaker
cabling (preferably in the telephone equipment
room). Disconnect all power before installing
equipment.
1. Mount the Zone Expansion Unit(s) (ZEU) to
either a wall, cabinet or a rack (below the
controller).
2. Connect 8-pin Molex from Controller to first
ZEU, and next ZEUs, if used.
NOTE: Up to 3 ZEUs can be used, providing
up to 56 paging and/or control zones.
3. Set DIP switches on each ZEU(s).
4. Set the Zone Option switches on the
Controller and ZEU(s).
NOTE: For each zone used, no matter what
its function, this switch needs to be set to one
of three settings for proper zone operation
before applying power to the system.
The Controller has eight switches for zones 1-8.
Each subsequent ZEU has switches for zones
9-24, 25-40 and 41-56.
Refer to the Zone Map and Zone Configuration
Tables filled out during facility paging system
design. You can find these in the PagePac®
System Installation and Configuration Guide.
5. Locate and mount all speakers in accordance
with the floor plan drawing for this
installation.
6. Connect each speaker to the appropriate
Home Run or Speaker-to-Speaker wiring
scheme as shown on the floor plan.
NOTE: Adjust all speakers per volume and
power requirements as noted on floor plan,
during or after installation.