background image

Valcom, Inc.
5614 Hollins Road
Roanoke, VA  24019
USA

P. 540-563-2000
F. 540-362-9800
www.valcom.com

Installation Manual V10.5

Valcom Wired Digital Clock

Current as of February 2017

V-D11025B, V-D11040B, V-2425B-6, and V-D2440B-6

Содержание V-2425B-6

Страница 1: ...5614 Hollins Road Roanoke VA 24019 USA P 540 563 2000 F 540 362 9800 www valcom com Installation Manual V10 5 Valcom Wired Digital Clock Current as of February 2017 V D11025B V D11040B V 2425B 6 and...

Страница 2: ...t Safety Instructions 3 Wall Mount Installation 4 10 Flag Mount Installation 11 19 Double Mount Installation 20 28 Adjustable Jumper Settings 29 Inputs System Side 2 Wire Digital Communication 30 3 Wi...

Страница 3: ...n protocol Using the wrong wiring format may damage the clock WARNING FIRE HAZARD Always follow your national and regional electrical codes or ordinances The AC power circuit for the clock must be att...

Страница 4: ...flat blade screwdriver a single gang box any equipment needed to install the gang box and any additional wiring needed to extend the signal power or ground cables You may also need a 1 4 inch drill 4...

Страница 5: ...evel with the floor If you are using an existing gang box the top of the gang box must be a minimum of three inches away from the ceiling 4 If you do not wish to attach the housing to the gang box pro...

Страница 6: ...es between the top rear edge of the housing and ceiling Confirm that the bottom of the mounting piece is level with the floor 5B Identify the keyholes towards the top of the back of the clock housing...

Страница 7: ...cil to trace the holes beneath each keyhole onto the wall Take the clock housing off the wall drill holes at the marked locations and add another two wall anchors 5G Run power and signal wires through...

Страница 8: ...e installing a digital clock that uses sync wire correction attach the wires to the appropriate sync wire ports Refer to the section Inputs Clock Side Sync Wire for instructions regarding each system...

Страница 9: ...into place 9 Detach the frame from the front of the clock housing by pulling the bottom and top edges away from the housing 10 Use the 6 19x1 2 screws to attach the display board to the housing NOTE...

Страница 10: ...ame onto the housing You should hear a snapping noise as the latches drop into place 14 Power the clock After testing the LED segments and presenting some diagnostic information the clock will display...

Страница 11: ...l Housing 6 19x1 2 screw 6 32x1 screw Quantity 1 1 4 4 Picture Included in Package Included in Pole Kit V DMKIT If any of the items listed in the kits are missing you may contact Valcom and order a re...

Страница 12: ...will also have to provide a Phillips head screwdriver a small flat blade screwdriver a single gang box any equipment needed to install the gang box and any additional wiring needed to extend the signa...

Страница 13: ...the two screws Set the screws and pole aside for later 4 Attach the mounting plate to the gang box using only two of the four long silver 6 32x1 screws With the mounting plate as a guide use the penci...

Страница 14: ...allation 5 Remove the mounting pole end cap and the plastic ring from one of the holes 6 Attach the flag mount end cap to the pole Confirm that the covering flap is attached to the side where the plas...

Страница 15: ...ntered holes and the 10 32x3 8 screw 8 Reattach the mounting plate this time using all four long silver 6 32x1 screws then insert the four 8 screws through the mounting plate and into the anchors 10 U...

Страница 16: ...ts through the hole in the adapter 12 Insert the four 8 32x7 16 screws through the internal tooth washers then through the adapter and finally into the pole Use a screwdriver to tighten the screws so...

Страница 17: ...ing For 4 0 Digit Clocks the holes will be on the top and bottom surfaces 15A If you are installing a digital clock that uses a 2 wire digital sync system attach the wires to the port as shown below 1...

Страница 18: ...drop into place 17 Use the 6 32x12 screws to attach the display board to the housing NOTE For 2 5 Digit clocks the holes for the screws will be on the left and right inner surfaces of the housing For...

Страница 19: ...he bottom of the base Attach the wires from the pole to the wires in the gang box then use the two black base screws to attach the other side of the base to the mounting plate 22 Power the clock After...

Страница 20: ...ll Housing 6 19x1 2 screw 6 32x1 screw Quantity 1 1 8 8 Picture Included in Package Included in Pole Kit V DMKIT If any of the items listed in the kits are missing you may contact Valcom and order a r...

Страница 21: ...will also have to provide a Phillips head screwdriver a small flat blade screwdriver a single gang box any equipment needed to install the gang box and any additional wiring needed to extend the sign...

Страница 22: ...the two screws Set the screws and pole aside for later 4 Attach the mounting plate to the gang box using only two of the four long silver 6 32x1 screws With the mounting plate as a guide use the penc...

Страница 23: ...entered holes and the 10 32x3 8 screw 6 Reattach the mounting plate this time using all four long silver 6 32x1 screws then insert the four 8 screws through the mounting plate and into the anchors 8 U...

Страница 24: ...m through the wire clamp 10 Insert the four 8 32x7 16 screws through the internal tooth washers then through each adapter and finally into the pole Use a screwdriver to tighten the screws so that the...

Страница 25: ...ams below for additional help or see the sections of this manual labeled 3 Wire Synchronous Sync Wire Communication Wiring Information or 2 Wire Digital Communication Wiring Information for additional...

Страница 26: ...ousing For 4 0 Digit Clocks the holes will be on the top and bottom surfaces 14A If you are installing digital clocks that use a 2 wire digital sync system attach the wires to the port as shown below...

Страница 27: ...drop into place 16 Use the M3 5 1 5x12 screws to attach a display board to each housing NOTE For 2 5 Digit clocks the holes for the screws will be on the left and right inner surfaces of the housing F...

Страница 28: ...the bottom of the base Attach the wires from the pole to the wires in the gang box then use the two black base screws to attach the other side of the base to the mounting plate 21 Power the clock Afte...

Страница 29: ...n Right Position Pins 1 2 Pins 2 3 Jumper 1 12 Hour Time Default 24 Hour Time Jumper 2 Display High Brightness Default Display Low Brightness Jumper 3 Display Time Only Default Alternate display betwe...

Страница 30: ...de 2 Wire Digital V A2412 or V A2416 V A2412B or V A2416B Valcom Master Clock V D2425B 6 or V D2440B 6 V C6124P and the V CCU are ordered as a V VCU Data In 2 Wire Digital Output to Clocks 24 VDC IN 2...

Страница 31: ...VAC Clock Circuit 10 Amp Contact Rating or or Clock Circuit 1 Clock Circuit 2 27 26 25 24 23 22 27 26 25 24 23 22 or means one pair of ports or the other You cannot for instance use port 23 for reset...

Страница 32: ...efer to the diagram for details The diagrams on the following pages indicate how wires should be run between the various ports on the clock and the network to allow for the use of Sync wire protocols...

Страница 33: ...00 5 11 00 5 13 00 5 15 00 5 17 00 5 19 00 5 21 00 and 5 23 00 58th minute 2 The hourly correction for 60 seconds every hour from XX 58 00 to XX 59 00 The daily correction 5 a m 5 p m is twelve correc...

Страница 34: ...land 110VAC 60 Hz is used to run the clock normally Applying a 25 second reset signal when minutes equal 00 and seconds equal 00 will cause an hourly correction Applying a 24 minute reset signal when...

Страница 35: ...Interface J1 1 2 3 4 5 6 7 8 9 J2 1 2 Relay N O COM Dry Contact Closure Description Midnight Reset or Once a Day Pulse Description Dukane Applying a 4 10 millisecond pulse on the minute line will inc...

Страница 36: ...ed as 1 4 starting with port 1 on the bottom and port 4 on the top 2 Wire Digital Master Mode During a loss of communication with the Master Clock the V D110XXB digital clock can act as a temporary ba...

Страница 37: ...be 41 99 The numbers shown on the left are examples Going down the list and entering every one of the examples exactly as shown will cause the clock to malfunction or use incorrect data Program your c...

Страница 38: ...rnate Date and Time Press the bottom button to switch between d or E d disables Alternating Time and Date E enables Alternating Time and Date NOTE Alternating Time and Date set through this method dis...

Страница 39: ...Zone Number Press the bottom button to advance the ID number of the clock This accepts the Zone Numbers 01 through 99 The Zone Number is used for displaying text messages like 911 bELL and FirE Consul...

Страница 40: ...Press the bottom button to switch between the numerical options below 01 Activates after 5 minutes 05 Activates after 45 minutes 09 Activates after 180 minutes 02 Activates after 10 minutes 06 Activa...

Страница 41: ...ly correction that takes 55 seconds and occurs between XX 59 05 and XX 59 00 It also performs two daily corrections one at 5 00AM and one at 5 00PM Each daily correction is made of twelve relay cycles...

Страница 42: ...from 00 to 99 For example a value of 98 will set a pulse duration of 1 minute and 38 seconds Set to 3 by default Setting 30 Set Sync Wire Time Input Type Allows the user to configure the sync wire typ...

Страница 43: ...Diagnostic 1 Protocol Verification 03 Diagnostic 3 Resets clock to Manufacturing Default and sets all hands to 12 05 Diagnostic 4 Full Mechanical and Electrical Test Begins automatically 02 Diagnosti...

Страница 44: ...ndicate PM or disappear to indicate AM When the display is set to the 24 hour format the full 24 hour time will appear on the display no other lights should appear Some examples 5 30 AM 12 hour format...

Страница 45: ...backup for about ten years In this mode it may drift from synchronized time by a few seconds for each year that the clock is without power Once power is restored to the clock the display will turn on...

Страница 46: ...do 1 For V D110XXB Make sure that JP6 is in the proper position Refer to Adjustable Jumper Settings for details and diagrams 2 For V D24XXB 6 Make sure that the polarity of the communication wire is...

Страница 47: ...ice charge will cover minor repairs major repairs will be subject to additional charges for parts and labor This Limited Warranty is in lieu of and excludes all other warranties expressed or implied a...

Отзывы: