Mixing Talkback and One-Way 
Paging

 

When using a Talkback Control Unit, one-way 
and talkback zones may be mixed on the same 
control unit.  The outgoing page on a talkback 
zone may also be expanded by adding one-way 
speakers. 

 

To make a zone one-way, simply add a V-1092 
volume control and Valcom one-way amplified 
speakers to that zone (maximum 40 per zone). 

 

To expand the outgoing page on a talkback 
zone, wire one-way amplified speakers in 
parallel with the talkback speakers on that zone 
(maximum 40 per zone).  Of course, when you 
do this you still will only be receiving talkback 
from the 45 ohm talkback speakers on the zone. 

 

 

NOTE:  When using one-way amplified 
speaker assemblies on a talkback control 
unit, a V-1092 Volume Control or a 
V-1094A Page Port Preamp may be used 
to attenuate the high level talkback audio 
level prior its appearance at the audio 
input of the one-way speakers (talkback 
audio is substantially higher in level in 
comparison to one-way audio). 

 

Talkback Speakers 

Valcom Talkback Speakers are available in 
many styles to accommodate virtually any 
environment.  Please refer to our complete list of 
speakers and options on our website at 
www.valcom.com. 
 
Our styles include: 

 

Wall Speakers 

 

Surface or Flush Mount 

 

Woodgrain or Paintable Metal 

 

Slimline style 

 

Corner Mount 

 

Double-sided style 

 

Pendant Speakers 

 

Ceiling Speakers 

 

With or without LED 

 

P-Tec for tile ceilings 

 

2x2 Lay-In with Backbox 

 

Desktop Speakers 

 

Desktop or Wall Mount 

 

Push Button Call Switch 

 

Doorplate / Intercom Speakers 

 

Flush Mount style 

 

Brass, Steel or Vandal-Resistant 

 

Surface Mount style 

 

Call Activity LED Indicator 

 
 

 

Horns 

 

Water-resistant 

 

Explosion-Proof 

 

Flexhorn 

 

Backboxes available 

 

SYSTEM INSTALLATION 

General 

For specific wiring information, consult the 
installation practice enclosed with the actual 
equipment you are using

 

Precautions 

Locate the Valcom equipment or cabling at least 
18" away from power supplies, electrical panels, 
or any equipment that generates electrical noise.  
Additionally, locate the Valcom equipment within 
6' of the Valcom or 1A2 power supply used to 
power the unit(s). 

 

Mounting 

The control equipment should be installed at the 
main distribution frame with the telephone 
system common equipment. 

 

Cabling 

Standard 22 or 24 AWG twisted pair telephone 
wire may be used for the speakers.  Talkback 
speakers require 1 pair (2 pairs when using 
speakers with call-in switches).  One-way 
amplified speakers require 2 pairs (refer to the 
One-Way Paging VSP). 

 

MAXIMUM CABLE LENGTH TO TALKBACK 
SPEAKERS  IS 800 FEET

 

 

DO NOT SPLIT PAIRS

 

 

Grounding 

For proper operation, the ground of the power 
supply must be connected to a reliable ground. 
 

CAUTION:  Using an electrical ground may 
put noise on the talkback. 

 

High Power Amplifiers 

In many cases an existing high power amplifier 
may be connected to a zone output of the control 
unit for one-way paging.  Simply insert a V-1092 
volume control and connect the zone audio 
output to the auxiliary input of the amplifier. 

 

NOTE:  YOU CANNOT INCREASE THE 
NUMBER OF TALKBACK SPEAKERS IN A 
ZONE THROUGH USE OF A HIGH POWER 
TALKBACK AMPLIFIER.