background image

 

       947793 

LED (+)

LED (-)

CONNECTS TO SPEAKER

IP TALKBACK

SPEAKER CONNECTION DETAILS

NETWORK

OUT ON POWER FAIL

-10 dB LINE

CALL SWITCH

SPEAKER OUT

LEVEL OUT

P6

P5

P3

P2

P4

  NETWORK

CONNECTION

MOUNTING

 BRACKET 

Packing List 

Qty. Item 

1 VIP-431-DS 
1 VSP 

Document 

 

MOUNTING 

Remove the screw holding the mounting bracket to 
the enclosure.  Mount the bracket using appropriate 
hardware such as #8 pan head crews.  After 
making the required connections, reattach the 
enclosure to the mounting bracket 
 

 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 
 
 
 
 
 

Figure 1.  Connections 

 
Network Connection 

The VIP-431-DS has one RJ-45 network connector 
on the rear panel. Use a standard Ethernet  
patch cable to connect the VIP-431-DS to  an 
Ethernet switch. (See Figure 1) 

 
 

Call Switch Connection 

The VIP-431-DS provides a call switch input via 
screw terminal connections. See Figure 1 for 
detailed connections. 
 

LED (+) and (-) Connection 

LED (+) and (-) is a current limited output designed 
to illuminate an optional LED. The LED is intended 
to provide visual indication of call progress. The 
LED illumination will flash when the call switch is 
pressed and will continue to flash until the call is 
answered. The LED illumination will be solid while a 
connection to the VIP-431-DS is established. 

-10 dB Line Level Out Connection 

The -10dBm Line Level Out may be connected to 
up to 40 Valcom Self Amplified Speakers in order to 
provide additional sound reinforcement in an area. 
 

Setup 

Information specific to your application will need to 
be programmed into the VIP-431-DS using a 
computer. The PC used for programming should be 
connected to the same subnet as the VIP-431-DS.  
Setup will be done using the IP Solutions Setup 
Tool. Download the latest version of the free IP 
Solutions Setup Tool from Valcom web site at 
www.valcom.com/vipsetuptool. 
 

TECHNICAL ASSISTANCE 

When trouble is reported, verify power is being 
supplied to the unit and there are no broken 
connections.  If a spare unit is available, substitute 
a spare unit for the suspected defective unit. 
 
Assistance in troubleshooting is available from the 
factory.  Call (540) 563-2000 and press 1 for 
Technical Support or via email at 
[email protected] 
 
When requesting assistance, you should include all 
available information.  It is strongly suggested that 
you go to the web site and review the information 
provided at http://www.valcom.com. 
 
Valcom equipment is not field repairable.  Valcom, 
Inc. maintains service facilities in Roanoke, VA.  
Should repairs be necessary, attach a tag to the 
unit clearly stating your company name, address, 
phone number, contact person and the nature of 
the problem. Send the unit to: 
 

Valcom, Inc. 

Repair & Return Dept. 

5614 Hollins Road 

Roanoke, Va. 24019-5056 

Отзывы: