Status / Calibration / Reset

 

A multifunction button is provided to display 
information, allow calibration and/or reset the 
VL520-IC configuration.  The button is located 
behind a pinhole in the top-center of the    
VL520-IC and can be depressed using a small 
diameter object, such as a toothpick.  The 
button provides different results depending on 
how long the button remains depressed. 
 

Status Mode 

Press the button for approximately 1 second 
and release and the Status display will show the 
current IP Address, Power Source status and 
the last four digits of the MAC address. 
 

Calibration Mode 

While the Status display is active, pressing the 
button again will put the VL520-IC in Calibration 
Mode.  Calibration mode allows the VL520-IC to 
adjust its light sensor to the ambient light in the 
room.  While in this mode, follow the prompts on 
the LED display to turn the room lights on/off.  
The calibration takes about 60 seconds, and the 
VL520-IC will display "Calibrated" when 
complete. 
 

Demo Mode 

While the VL520-IC is in Calibration Mode, 
pressing the button again will enable Demo 
Mode.  In this mode, the VL520-IC will display a 
scrolling sample message and the flashers will 
flash.  Demo Mode will display for about 30 
seconds then the VL520-IC returns to normal 
operation. 
 

Reset Modes 

Pressing the button continuously for greater 
than 10 seconds, but less than 20 seconds, will 
perform a soft reset on the VL520-IC.  The IP 
address will be reset to the factory default 
setting.  Other configuration items will not be 
affected. 
Pressing the button continuously for greater 
than 20 seconds will perform a hard reset on the 
VL520-IC.  All of the configuration items 
(including the password) will be reset to factory 
default settings.

Setup 

The VL520-IC will automatically acquire an IP 
address (using DHCP) and connect to the 
InformaCast server when connected to the 
network and powered up.  Information specific 
to your application will need to be programmed 
into the InformaCast server.  Refer to the 
InformaCast documentation for further 
information. 
 

TECHNICAL ASSISTANCE 

Assistance is available from the factory when 
problems are encountered.  Call (540) 563-2000 
and press 1 for Technical Support or visit our 
website at http://www.valcom.com 
 
Valcom, Inc. equipment is not field repairable.  
Valcom maintains service facilities in Roanoke, 
VA. 
Should repairs be necessary, attach a tag to the 
unit clearly stating company name, address, 
phone number, contact person, and the nature 
of the problem. 
Send the unit to: 
 

Valcom, Inc. 

Repair and Return Dept. 

5614 Hollins Road 

Roanoke, VA 24019-5056 

 

WARRANTY 

Warranty information may be found on our 
website at www.valcom.com/warranty. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 