manualshive.com logo in svg
background image

 

 

                  3 

                                           

VM-186

RJ45

BLUE

ORANGE

GREEN

BROWN

BROWN

BLUE

N/O RELAY OUTPUT

AUDIO INPUT

CONTACT CLOSURE INPUT

AUDIO OUTPUT

WHITE/BLUE

BLUE

WHITE/ORANGE

ORANGE

WHITE/GREEN

GREEN

WHITE/BROWN

BROWN

Status Indicator Lights 

The VE8004/VE8004R has 3 status indication 
lights on the front panel: 

 

STATUS: 

Flashes during normal operation and 

solid during system startup.    

 

LINK:

 Indicates 100 Mbit Ethernet connection 

when illuminated.  No activity indicates 10 Mbit 
connection. 

 

ACT:

 Indicator flashes to indicate network activity. 

 

Signal Connections 

The VE8004/VE8004R has five signal connectors 
on the rear panel: 

 

  1 RCA jack for AUX audio input 

  4 RJ-45 connectors for audio and relay 

 

connections for each networked channel 

 

AUX Input

: Local audio may be input via the 

rear panel RCA jack.  Nominal input impedance 
is 600 Ohms.  Connect any compatible audio 
source using an RCA patch cable.  Audio 
supplied through the rear panel RCA jack is 
transformer coupled to both Audio Out channels 
when Audio Out is idle.  This is typically

  

used for background music.

 

 

 

 

 

 

 
 
 

Rear View 

 
Networked Channels: 

Access to the networked 

audio is via four rear panel RJ-45 connectors.  
Provided with the VE8004/VE8004R are four     
RJ-45 patch cables and four VM-186 RJ-45 
Connectors.  Signals connections are made by 
connecting one end of a patch cable to the 
VE8004/VE8004R and the other to the VM-186 
connector.  Access to the signals is via screw 
terminal connections or 110-style punchdown block 
on the VM-186 (see Figure 2).  Signals are present 
on pairs of pins as shown in Figure 2.

 
 
 
 
 
 
 
 
 
 
 

 
 

Figure 2.  VM-186 RJ-45 Connector 

 

Setup 

Information specific to your application will need 
to be programmed into the VE8004/VE8004R 
using a computer.  The PC used for programming 
should be connected to the same subnet as the 
VE8004/VE8004R.  Setup will be done using the 
IP Solutions Setup Tool. Download the latest 
version of the free IP Solutions Setup Tool from 
Valcom website at www.valcom.com/vipsetuptool. 
 

TECHNICAL ASSISTANCE 

When trouble is reported, verify power is being 
supplied to the unit and there are no broken 
connections.  If a spare unit is available, substitute 
a spare unit for the suspected defective unit. 

 

Assistance in troubleshooting is available from the 
factory. Call (540) 563-2000 and ask for Class 
Connection Technical Support. 

Valcom equipment is not field repairable.  Valcom, 
Inc. maintains service facilities in Roanoke, VA.  
Should repairs be necessary, attach a tag to the 
unit clearly stating your company name, address, 
phone number, contact person and the nature of 
the problem. Send the unit to: 

Valcom, Inc. 

Repair & Return Dept. 

5614 Hollins Road 

Roanoke, Va. 24019-5056  

 
 
 
 
 
 
 
 
 
 
 
 
 

Отзывы: