![Vaisala WAC155 Скачать руководство пользователя страница 50](http://html1.mh-extra.com/html/vaisala/wac155/wac155_user-manual_3468399050.webp)
6. Troubleshooting
6.1 Problem Situations
Table 10 Problem Situations and Their Remedies
Problem
Possible Cause
Action
The data collecting
system does not receive
data.
Improper or loose connections
Check the wiring and tighten the
screw terminals.
Incorrect messaging settings
Check and correct the messaging
settings through the service
connection.
Power failure
Make sure that the power supply is
connected and operational.
Sensor shaft heating is
not working.
Heating power is not connected
properly.
Check the wiring and tighten the
screw terminals.
Heating is not enabled in the
transmitter settings.
Check and correct the transmitter
settings using the service connection.
The heating power supply has a
power failure.
Make sure that the power supply is
connected and operational.
MWV message returns a
null field (,,) for wind
speed or direction
reading.
Parameter
spdvoltlimit
or
dirvoltlimit
has too high a
value and the sensor is
considered absent or faulty.
Set a lower value for the parameter.
See
WA25 system returns
null fields (,,) or
incorrect values.
Parameter
spdvoltlimit
,
dirvoltlimit
, or
powersave
has a wrong value.
For WA25, set:
spdvoltlimit
= 0
dirvoltlimit
= 0
powersave
= 0
See
Wind vane returns
readings with constant
deviation from the
correct direction.
The cross arm is incorrectly
aligned or the
offset
parameter value is wrong.
Check the alignment. If correct
mounting is impossible or
inconvenient, correct the alignment
with the
offset
parameter. See
WAC155 User Guide