calibmax
20 mA calibration value for analog vane (default: 2640)
value
Value for the option
For a WA25 system, use the following settings:
•
powersave
= 0
•
spdvoltlimit
= 0
•
dirvoltlimit
= 0
See also
Example
>setmea offset 0.318
GAINCORR = 0.10100
OFFSET = 0.31800
POWERSAVE = 1
ALLOWEDSPDCHANGE = 10.0
MAXINVALIDSPDCOUNT = 2
THIES = 0
CALIBMIN = 540
CALIBMAX = 2640
More information
‣
Wiring WAA252 and WAV252 with WAC155 (page 23)
4.3.8 SETCOM
The
SETCOM
command configures the data communication parameters.
SETCOM [portnumber] [baudrate] [databits] [parity] [stopbits] [txddelay]
<value><cr>
In normal use,
portnumber
must always be omitted. The port number 1 is used
only for production testing and is not user-accessible.
portnumber
Number of the COM port to configure, 0 or 1. If omitted, the configuration
applies to the current port in use.
baudrate
Baud rate of the port. Possible values: 300, 600, 1200 2400, 4800, 9600,
or 19200. Default value: 9600.
databits
Number of data bits, 7 or 8. Default value: 8.
parity
Parity: ODD, EVEN, or NONE. Default value: NONE.
Chapter 4 – Operation
39